HP 37717C manual SDH Alarm Indicators, Sonet Alarm Indicators Option

Models: 37717C

1 38
Download 38 pages 57.42 Kb
Page 31
Image 31

Getting Started

Monitoring Status

SDH Alarm Indicators

These are active when an SDH signal is received.

FRAME LOSS Loss Of Frame has been detected.

LOSS OF

 

POINTER

Loss of pointer has been detected.

MS-AIS

Multiplexer Section AIS has been detected.

AU-AIS

Path AIS has been detected.

CLOCK LOSS

The transmitter clock is not synchronized to the

 

selected reference.

MS-RDI

Multiplexer Section RDI (FERF) has been detected.

HP-RDI

Path RDI (FERF) has been detected.

TU-AIS

TU Path AIS has been detected. .

LP-RDI

TU Path RDI (FERF) has been detected. .

POINTER

 

ADJUST

A pointer change in the foreground signal has been

 

detected.

SONET Alarm Indicators (Option 120)

These are active when a SONET signal is received.

LOF/SEF

Loss of Frame or Severely Errored Frame has been

 

detected. Status message on bottom of display states

 

which has occurred.

LOP-P/LOP-V

Loss of Pointer has been detected.

AIS-L

Line AIS has been detected.

AIS-P

STS Path AIS has been detected.

CLOCK LOSS

The transmitter clock is not synchronized to the

 

selected reference.

RDI-L

Line Remote Defect Indication (RDI) has been

 

detected.

RDI-P

STS Path RDI has been detected.

AIS-V

Virtual Tributary path AIS has been detected.

29

Page 31
Image 31
HP 37717C manual SDH Alarm Indicators, Sonet Alarm Indicators Option