P700m LEDs
LED ID | Color | Name | Comments |
|
|
|
|
1 | Amber | CR10: Thermal Alert | This LED is not used. |
2 | Amber | CR9: System Error | The controller ASIC has locked up and cannot |
|
|
| process any commands. |
|
|
|
|
3 | Amber | CR1: Diagnostics Error | One of the server diagnostics utilities has detected a |
|
|
| controller error. |
4 | Amber | CR2: Drive Failure | To determine which drive has failed, check the Fault |
|
|
| LED of each physical drive connected to the |
|
|
| controller. |
|
|
|
|
5 | Green | CR3: Activity | Port 2 is active. |
6 | Green | CR4: Activity | Port 1 is active. |
7 | Green | CR5: Command Outstanding | The controller is working on a command from the |
|
|
| host driver. |
8 | Green | CR6: Controller Heartbeat | When the controller is in good health, this LED |
|
|
| flashes every two seconds. |
9 | Green | CR7: Gas Pedal | This LED, together with the Idle Task LED (next item), |
|
|
| indicates the amount of controller CPU activity. For |
|
|
| more information, see the following table. |
|
|
|
|
10 | Green | CR8: Idle Task | This LED, together with the Gas Pedal LED (previous |
|
|
| item), indicates the amount of controller CPU activity. |
|
|
| For more information, see the following table. |
|
|
|
|
Gas Pedal LED status | Idle Task LED status | Controller CPU activity level |
|
|
|
Off | Flashing | |
Flashing | Off | |
On steadily | Off | |
On steadily | On steadily |