Online/activity

Fault/UID LED

Interpretation

LED (green)

(amber/blue)

 

 

 

 

Flashing regularly

Off

Do not remove the drive. Removing a drive may terminate the

(1 Hz)

 

current operation and cause data loss.

 

 

The drive is rebuilding, erasing, or it is part of an array that is

 

 

undergoing capacity expansion or stripe migration.

 

 

 

Flashing irregularly

Amber, flashing

The drive is active, but a predictive failure alert has been received

 

regularly (1 Hz)

for this drive. Replace the drive as soon as possible.

 

 

 

Flashing irregularly

Off

The drive is active, and it is operating normally.

Off

Steadily amber

A critical fault condition has been identified for this drive, and the

 

 

controller has placed it offline. Replace the drive as soon as

 

 

possible.

 

 

 

Off

Amber, flashing

A predictive failure alert has been received for this drive. Replace

 

regularly (1 Hz)

the drive as soon as possible.

Off

Off

The drive is offline, a spare, or not configured as part of an array.

Identifying the status of an HP SmartDrive

HP SmartDrives are the latest HP drive technology, and they are supported beginning with ProLiant Gen8 servers and server blades. The HP SmartDrive is not supported on earlier generation servers and server blades. Identify an HP SmartDrive by its carrier, shown in the following illustration.

When a drive is configured as a part of an array and connected to a powered-up controller, the drive LEDs indicate the condition of the drive.

Item

LED

Status

Definition

 

 

 

 

1

Locate

Solid blue

The drive is being identified by a host application.

 

 

Flashing blue

The drive carrier firmware is being updated or requires an update.

 

 

 

 

2

Activity ring

Rotating green

Drive activity

 

 

Off

No drive activity

 

 

 

 

3

Do not remove

Solid white

Do not remove the drive. Removing the drive causes one or more of

 

 

 

the logical drives to fail.

 

 

Off

Removing the drive does not cause a logical drive to fail.

 

 

 

 

4

Drive status

Solid green

The drive is a member of one or more logical drives.

 

 

Flashing green

The drive is rebuilding or performing a RAID migration, stripe size

 

 

 

migration, capacity expansion, or logical drive extension, or is

 

 

 

erasing.

 

 

 

 

Drive procedures 80