ISA Configuration Utility Messages: Dell™ Precision™ WorkStation 610 Mini Tower Systems

Overview ICU Error Messages Configuration Manager Messages

Overview

The ISA Configuration Utility (ICU) and its Configuration Manager are capable of identifying problems and alerting you to them. Both utilities can alert you to problems with card configuration as well as problems that prevent proper operation of the utility. This appendix describes each type of message and lists the possible causes and actions you can take to resolve any problems indicated by a message. See the following tables to locate your message and identify any possible corrective actions.

ICU Error Messages

The ICU can display a variety of error messages while in operation. These messages alert you to problems that prevent the ICU from running correctly, as well as informing you of resource conflicts that prevent the configuration of various cards in your computer. If you receive a message from the ICU, see Table C-1 for suggestions on resolving any problems indicated by the message.

Table C-1. Configuration Utility Messages
MessageProbable Cause

 

 

 

 

Out of memory

Either of these messages can

Memory allocation failed

appear if the system runs out of

 

memory during your operation.

 

 

Corrective Action

Disable any terminate-and-stay-resident (TSR) programs or any unneeded device drivers.

Not enough memory to run the

ICU

This message appears when you start the ICU if the system does not have enough memory to run the utility.

Can't open index file.

This file is required for ICU to run.

No Configuration Manager.

At least one Plug and Play card in your system is not configured due to conflicts. These are marked "config err" in the list of configured cards.

Due to conflicts, the ICU could only configure some Plug and Play cards in your system. Unconfigured cards are marked "config err" in the list of configured

The ICU cannot find the index file for its database.

The device driver needed by the ICU is corrupted or is not correctly configured.

The Configuration Manager or the ICU cannot configure at least one Plug and Play expansion card because of resource conflicts with one or more cards.

Make sure to switch to drive A before attempting to start the utility.

Verify that the following device statement appears in your config.sys file: device= drive:\ directory\ drivers\dos\dwcfgmg.sys

In this statement, drive and directory represent the drive and directory where the driver resides. The default is c:\plugplay.

You must reconfigure the conflicting card(s). To find the conflicting card, perform the following steps:

1.Select the Plug and Play expansion card marked with config err, and then click Modify.

The Card Configuration dialog box displays the functions assigned to the Plug and Play expansion card.

2.Select a function and then click Settings. Click