3.Using the marked mid-weight slide-mounting alignment tool, mark the front and rear columns of the rack.

Item

Description

1Mark for HP 5U servers

2Mark for HP 4U servers

3Mark for HP 2U and HP 3U servers

4.Remove the top pin from the mid-weight outer slide assemblies.

NOTE: All M5 screws must be torqued to 6.2 Nm (55 lb).

5.Install the M5 barrel nuts on the rack columns.

6.Install the mid-weight outer slide assemblies by aligning the center pin of the mid-weight outer slide assemblies with the markings on the front and rear of the rack columns.

7.Screw the M5 x 30-mm screws to the mid-weight outer slide assemblies to secure it to the rack.

WARNING: Two people are needed to align and install the server properly. Do not install the server with the mid- weight inner slides extended.

8.Slide the server into the mid-weight outer slide assemblies.

9.Connect the cables to the server.

Page 7
Image 7
HP c8000 manual Description