System Overview

2.4 Specifications

This section includes the environmental, electrical, and physical specifications for the systems covered in this guide. Where provided, metric statistics are given in parenthesis. Specifications are subject to change without notice.

Table 2-5

Environmental Specifications (Factory Configuration)

Parameter

Operating

Non-operating

Ambient Air Temperature 50o to 95o F (10o to 35o C, max. rate of change < 10°C/Hr)

-22oto 140o F (-30oto 60o C, max.

rate of change < 20°C/Hr)

Shock (w/o damage)

 

5 Gs [1]

20 Gs [1]

 

 

 

 

Vibration

0.000215

G2/Hz, 10-300 Hz

0.0005 G2/Hz, 10-500 Hz

 

 

 

 

Humidity

10-90%

Rh @ 28o C max.

5-95% Rh @ 38.7o C max.

 

 

wet bulb temperature

wet bulb temperature

 

 

 

Maximum Altitude

10,000 ft (3048 m) [2]

30,000 ft (9144 m) [2]

 

 

 

 

 

NOTE:

 

 

 

 

[1]

Peak input acceleration during an 11 ms half-sine shock pulse.

 

[2]

Maximum rate of change: 1500 ft/min.

 

Table 2-6

 

Power Supply Electrical Specifications

 

 

Parameter

Value

 

 

Input Line Voltage:

 

Nominal:

100–240 VAC

Maximum

90–264 VAC

 

 

Input Line Frequency Range:

 

Nominal

50–60 Hz

Maximum

47–63 Hz

 

 

Energy Star 4.0 with 80Plus Bronze-level compliancy

 

SFF

Optional

MT

Optional

 

 

Maximum Continuous Power:

 

SFF

240 watts

MT

300 watts

NOTE:

Optional Energy Star 4.0 with 80-Plus Bronze-level compliant power supply unit available for both form factors.

 

2-10

www.hp.com

Technical Reference Guide