Input/Output Interfaces

5.2SATA Interfaces

These systems provide four serial ATA (SATA) interfaces that support tranfer rates up to 3.0 Gb/s and offer RAID data protection functionality. The SATA interface duplicates most of the functionality of the EIDE interface through a register interface that is equivalent to that of the legacy IDE host adapter.

5.2.1 SATA Connector

The standard 7-pin SATA connector is shown in the figure below.

Pin 1Pin 7

AB

Figure 5-1. 7-Pin SATA Connector (P60-P63 on system board).

Table 5-1.
7-Pin SATA Connector Pinout

Pin

Description

Pin

Description

 

 

 

 

1

Ground

6

RX positive

 

 

 

 

2

TX positive

7

Ground

 

 

 

 

3

TX negative

A

Holding clip

 

 

 

 

4

Ground

B

Holding clip

 

 

 

 

5

RX negative

--

--

 

 

 

 

5.2.2 AHCI/RAID Support

The SATA controller of the SB700 South Bridge can be set operate in either an IDE or AHCI RAID configuration. The AHCI RAID configuration supports RAID 0 and RAID 1 for improving performance and/or reliability. Applied to systems with only one hard drive, AHCI RAID can improve system performance somewhat through use of native command queuing (NCQ). True fault tolerance requires the use of two or more hard drives to allow mirroring, parity, and/or striping.

CAUTION: Changing the storage mode should always be preceded by backing up all hard rive data onto secondary media.

RAID 0—Striping with Two Hard Drives

RAID 0 uses striping to improve performance but does not provide any fault tolerance. The lack of redundancy (a failed drive ruins the whole array) results in less than half the reliability of a single hard drive. Although these systems support RAID 0, it is not the recommended configuration.

 