QuickSpecs
HP ProLiant DL120 Generation 6
Standard Features
Server Power Cords North America | One 6' Highline |
Japan | One 6' Highline (IEC) power cord and one 6' Lowline power cord ship |
| standard |
ROW | One 6' Highline (IEC) power cord ships standard |
NOTE: HP ProLiant DL120 G6 server ship standard worldwide with a C13 to C14 2M Highline jumper cord. Japanese models also include a 2M Lowline power cord. If customers require a local power cord, they can check the power cord matrix for the appropriate country specific cord. Please see the following power cord matrix: http://www.hp.com/go/powercordmatrix.
Power Supply | |
|
|
UPS and PDU Power Please see the UPS and PDU cable matrix's on the HP Power Protection and Management page.
Cord Matrix Under Power Cords, click on the "HP Power Cord Matrix" link. That link will list cable descriptions, requirements, and specifications for UPS and PDU units. Please see the following link: www.hp.com/products/powercords.
System Fans | 4 dual rotor fans ship standard. |
|
|
Required Cabling For required cabling information, refer to the Web site at:
Operating Systems and Microsoft Windows Server
Virtualization Software Red Hat Enterprise Linux (RHEL)
SUSE Linux Enterprise Server (SLES)
NOTE: For more information on HP's Certified and Supported ProLiant Servers for OS and Virtualization Software and latest listing of software drivers available for your server, please visit our Support Matrix at: http://www.hp.com/go/supportos and our driver download page http://www.hp.com/support/DL120G6
Rack Airflow | Rack 10000 G2 series Cabinets | |
Requirements | The increasing power of new | |
| efficiency for | |
| maximum cooling, allowing these racks to be fully loaded with servers using the latest processors. | |
| CAUTION: If a | |
| adequate airflow and to prevent damage to the equipment: | |
| Front and rear doors: If your 42U server rack includes closing front and rear doors, you must | |
| allow 830 square inches (5,350 sq cm) of hole evenly distributed from top to bottom to | |
| permit adequate airflow (equivalent to the required 64 percent open area for ventilation). | |
| Side: The clearance between the installed rack component and the side panels of the rack | |
| must be a minimum of 2.75 inches (7 cm). | |
| CAUTION: Always use blanking panels to fill all remaining empty front panel | |
| This arrangement ensures proper airflow. Using a rack without blanking panels results in improper | |
| cooling that can lead to thermal damage. | |
| NOTE: For additional information, refer to the Setup and Installation Guide or the Documentation | |
| CD provided with the server. | |
|
|
|
DA - 13504 Worldwide QuickSpecs — Version 8 — 8/20/2010 | Page 9 |