QuickSpecs

HP ProLiant DL120 Generation 6

Technical Specifications

System Unit

Dimensions (H x W x D) 4.32 x 44.81 x 70.0 mm (1.69" x 17.64" x 27.56")

 

(with bezel)

 

 

 

Weight

Maximum

31.49 lb (14.3kg)

 

(approximate)

(four hard drives, power

 

 

 

supply, and processor

 

 

 

installed)

 

 

 

Minimum

28.2lb (12.8kg)

 

 

(one hard drive, power

 

 

 

supply, and processor

 

 

 

installed)

 

 

Input Requirements

Range Line Voltage

90 - 132 VAC,

 

(per power supply)

 

180 - 264 VAC

 

 

Rated Input Current

6 A (at 100 VAC),

 

 

 

3 A (at 200 VAC)

 

 

Rated Input Frequency

47 to 63 Hz

 

 

Rated Input Power

<550W (at 100 VAC)

 

 

 

550W (at 200 VAC)

 

BTU Rating

Maximum

1314 BTU/hr (at 100 VAC),

 

 

 

1314 BTU/hr (at 200 VAC)

 

Power Specifications

To review typical system power ratings use the Power Advisor which is

 

 

available via the online tool located at URL: www.hp.com/go/proliant-

 

 

energy-efficientor www.hp.com/go/hppoweradvisor

 

 

- Click on the system of interest. Example: DL120 G6

 

 

- Follow the instructions of the next screens.

 

Power Supply Output

Rated Steady-State

400 W (at 100 VAC),

 

(per power supply)

Power

400 W (at 200 VAC)

 

 

Maximum Peak Power

430 W (at 100 VAC),

 

 

 

430 W (at 200 VAC)

 

System Inlet

Operating

10° to 35°C (50° to 95°F) at sea level with an

 

Temperature

 

altitude derating of 1.0°C per every 305 m

 

 

 

(1.8°F per every 1000 ft) above sea level to a

 

 

 

maximum of 3050 m (10,000 ft), no direct

 

 

 

sustained sunlight. Maximum rate of change

 

 

 

is 10°C/hr (18°F/hr). The upper limit may be

 

 

 

limited by the type and number of options

 

 

 

installed.

 

 

 

System performance may be reduced if

 

 

 

operating with a fan fault or above 30°C

 

 

 

(86°F).

 

 

Non-operating

-30° to 65°C (-22° to 149°F). Maximum rate of

 

 

 

change is 20°C/hr (36°F/hr).

 

Relative Humidity

Operating

10 to 90% relative humidity (Rh), 28°C

 

(non-condensing)

 

(82.4°F) maximum wet bulb temperature, non-

 

 

 

condensing.

 

 

Non-operating

5 to 95% relative humidity (Rh), 38.7°C

 

 

 

(101.7°F) maximum wet bulb temperature,

 

 

 

non-condensing.

 

Altitude

Operating

3050 m (10,000 ft). This value may be limited

 

 

 

by the type and number of options installed.

 

 

 

Maximum allowable altitude change rate is

 

 

 

457 m/min (1500 ft/min).

 

 

Non-operating

9144 m (30,000 ft). Maximum allowable

 

 

 

altitude change rate is 457 m/min (1500

 

 

 

ft/min).

DA - 13504 Worldwide QuickSpecs — Version 8 — 8/20/2010

Page 30

Page 30
Image 30