| Pressure Control |
|
|
|
|
|
| Digital Display Messages |
|
| ||||
|
|
|
|
|
|
|
| • | Digital messages are not available on all sprayers | |||
|
| WARNING |
| |||||||||
|
|
| • | Blinking LED total count equals digital error code | ||||||||
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
| i.e., two blinks is the same as E=02 | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| Relieve pressure before repair, page 5. |
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |||||
| DISPLAY* |
| SPRAYER OPERATION |
| INDICATION |
|
| ACTION | ||||
|
|
|
|
|
|
| ||||||
| No Display |
| Sprayer may be pressurized | Loss of power or display not |
| Check power source. Relieve pressure | ||||||
|
|
|
|
|
|
| connected |
|
| before repair or disassembly. Verify display | ||
|
|
|
|
|
|
|
|
|
|
| is connected. | |
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
| Sprayer may be pressurized | Pressure less than |
| Increase pressure as needed | ||||
|
|
|
|
|
|
| 200 psi (14 bar, 1.4 MPa) |
|
|
| ||
| ti6314a |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| ||||
|
| psi |
| Sprayer is pressurized. Power is applied. | Normal operation |
| Spray | |||||
|
|
| (Pressure varies with tip size and |
|
|
|
|
|
| |||
|
| bar |
| pressure control setting.) |
|
|
|
|
|
| ||
|
| MPa |
|
|
|
|
|
|
|
|
| |
| ti6315a |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
| Sprayer stops. Engine is running. | Exceeded pressure limit |
| 1. | Check fluid path for clogs, such as | |||
|
|
|
|
|
|
|
|
|
|
|
| clogged filter. |
|
|
|
|
|
|
|
|
|
|
| 2. | Open prime valve and gun if running |
| ti6316a |
|
|
|
|
|
|
|
| AutoClean. | ||
|
|
|
|
|
|
|
|
|
|
| 3. | Use Graco paint hose, 1/4 in. x 50 ft |
|
|
|
|
|
|
|
|
|
|
|
| minimum. Smaller hose or metal braid |
|
|
|
|
|
|
|
|
|
|
|
| hose may result in pressure spikes. |
|
|
|
|
|
|
|
|
|
|
| 4. | Replace transducer if fluid path is not |
|
|
|
|
|
|
|
|
|
|
|
| clogged and proper hose is used. |
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
| Sprayer stops. Engine is running. | Pressure transducer faulty, bad |
| 1. | Check transducer connection. | |||
|
|
|
|
|
|
| connection or broken wire |
| 2. | Disconnect and reconnect transducer | ||
|
|
|
|
|
|
|
|
|
|
|
| plug to ensure good connection with |
| ti6317a |
|
|
|
|
|
|
|
| control board socket. | ||
|
|
|
|
|
|
|
|
|
|
| 3. | Open prime valve. Replace sprayer |
|
|
|
|
|
|
|
|
|
|
|
| transducer with known good |
|
|
|
|
|
|
|
|
|
|
|
| transducer and run sprayer. Replace |
|
|
|
|
|
|
|
|
|
|
|
| transducer if sprayer runs or control |
|
|
|
|
|
|
|
|
|
|
|
| board if sprayer does not run. |
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
| Sprayer stops. Engine is running. | High clutch current |
| 1. | Check wiring connections. | |||
|
|
|
|
|
|
|
|
|
|
| 2. | Measure: 1.2 +0.2Ω (GMAX II 3900); |
|
|
|
|
|
|
|
|
|
|
|
| 1.7 +0.2Ω (GMAX II 5900/ 7900) |
| ti6318a |
|
|
|
|
|
|
|
| across clutch field at 70°F. | ||
|
|
|
|
|
|
|
|
|
|
| 3. | Replace clutch field assembly. |
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
| Sprayer stops. Engine is running. | Loss of paint to pump or severe |
| 1. | Check for empty paint condition, clogged | |||
|
|
|
|
|
|
| pressure loss |
|
|
| inlet strainer, failed pump or severe leak. | |
| (with constant |
|
|
|
|
|
|
| 2. | Reduce pressure and turn pump | ||
|
|
|
|
|
|
|
|
| switch OFF and ON to restart pump. | |||
| green LED) |
|
|
|
|
|
|
| 3. | Watch dog function can be deactivated | ||
|
|
|
|
|
|
|
|
|
|
|
| by turning WatchDog switch OFF. |
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
| Sprayer stops. Engine is running. | Pressure greater than |
| 1. | Open prime valve and gun. | |||
|
|
|
|
|
|
| 2000 psi (138 bar, 14 MPa) while |
| 2. | Verify no flow obstructions or clogged | ||
| ti6320a |
|
|
| in Flush Timer Mode |
|
| filter. | ||||
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
*Error codes also appear on control board as a blinking red LED. LED is an alternate to digital messages.
1.Remove two screws (71) and swing down cover (130).
2.Start engine. Blink count is the same as error code(E=0X).
After a fault, follow these steps to restart sprayer:
1.Correct fault condition
2.Turn sprayer OFF
3.Turn sprayer ON
14 | 311046H |