HP ML370 manual Technical Specifications

Models: ML370

1 50
Download 50 pages 57.1 Kb
Page 47
Image 47

QuickSpecs

HP ProLiant ML370 Generation 6

Technical Specifications

System Unit

Tower Dimensions

18.52 x 9.75 x 29.12 in (47.04 x 24.77 x 73..96 cm)

 

(H x W x D) (with bezel)

 

 

 

Rack Dimensions

6.88 x 19.03 x 27.53 in (17.48 x 48.34 x 69.93 cm)

 

(H x W x D) (with bezel)

 

 

 

Tower Weight

Maximum

99.2 lbs (45.00 kg)

 

(approximate)

(All hard drives, power

 

 

 

supply, and processor

 

 

 

installed)

 

 

 

Minimum

66.14 lbs (30.00 kg)

 

 

(one hard drive, power

 

 

 

supply, and processor

 

 

 

installed)

 

 

Rack Weight

Maximum

85.91 lbs (38.97 kg)

 

(approximate)

(All hard drives, power

 

 

 

supply, and processor

 

 

 

installed)

 

 

 

Minimum

52.90 lbs (24.00 kg)

 

 

(one hard drive, power

 

 

 

supply, and processor

 

 

 

installed)

 

 

Input Requirements

Rated Line Voltage

90 - 132 VAC,

 

(per power supply)

 

180 - 264 VAC

 

 

Rated Input Current

7.5A (at 100 VAC),

 

 

 

3.8A (at 200 VAC)

 

 

Rated Input Frequency

47 to 63 Hz

 

 

Rated Input Power

980W (at 100 VAC)

 

 

 

1035W (at 120 VAC)

 

 

 

1170W (at 240 VAC)

 

BTU Rating

Maximum

460W - 1773 BTU / hr (at 120 VAC), 1715 (at

 

 

 

240 VAC)

 

 

 

750W - 2892 BTU / hr (at 120 VAC), 2797 (at

 

 

 

240 VAC)

 

 

 

1200W - 3530 BTU / hr (at 120 VAC), 4600

 

 

 

(at 240 VAC)

 

Power Specifications

To review typical system power ratings use the HP Power Advisor which

 

 

is available via the online tool located at URL: www.hp.com/go/proliant-

 

 

energy-efficient

 

 

 

- Click on the system of interest. Example: DL370 G6 or ML370 G6

 

 

- Follow the instructions of the next screens.

 

Power Supply Output

Rated Steady-State

460 W (at 100 VAC)

 

(per power supply)

Power

 

 

 

Maximum Peak Power

460 W (at 200 VAC)

 

 

 

460 W (at 100 VAC)

 

 

 

460 W (at 200 VAC)

 

 

 

NOTE: See Power Supply Specifications

 

 

 

tables for complete details on 460W PSU and

 

 

 

optional 750W and 1200W Power Supply

 

 

 

Options.

 

System Inlet

Operating

10° to 35°C (50° to 95°F) at sea level with an

 

Temperature

 

altitude derating of 1.0°C per every 305 m

 

 

 

(1.8°F per every 1000 ft) above sea level to a

 

 

 

maximum of 3050 m (10,000 ft), no direct

 

 

 

sustained sunlight. Maximum rate of change

DA - 13242 Worldwide QuickSpecs — Version 21 — 3-29-2010

Page 47

Page 47
Image 47
HP ML370 manual Technical Specifications