5.Use the provided Phillips screwdriver to remove the screw 4 from the lamp cover.

6.Remove the cover 5.

7.On the left side of the lamp module, push the electrical connector 6 up to disengage it from the projector base.

8.Remove the three screws 7 from the lamp module.

9.Pull out the lamp module 8.

WARNING: To reduce the risk of personal injury, do not

! drop the lamp module or touch the glass bulb. The glass may shatter and cause an injury if it is dropped.

To replace the lamp module, reverse the previous steps.

After replacing the lamp module, remember to reset the lamp hours in the on-screen menu.

IMPORTANT: This lamp contains < 0.125 percent mercury by weight. If the projection lamp breaks, the mercury may be released into the atmosphere. Please follow applicable federal, state, and local regulations for disposal and/or recycling.

1-30MP1600 Microportable Projector