10
Common Parameters set at Factory
MSG | = | COMMON | |
DELAY | = | 000 mm | |
WIDTH | = | 08 | mm |
HEIGHT | = | 13 | mm |
DENSITY = | 4 |
| |
FONT | = | FONT 2 | |
DIRECT | = | ←ABC | |
SPEED | = | 30.5 m/min |
DT Tune
The DT Tune sub menu is where adjustments to date code formatting are made. The settings in this menu apply to all messages printing dates.
∙
∙
MX SIZE: Sets the number of characters in month code. For a value of 2, a two digit number corresponding to the month is printed. For a value of 3, the three letter abbreviation for the month is printed
DT TRIM: Sets how month and day characters with leading zeros are printed. There are three options
o2007.01.01: Prints leading zeros in day and month.
o2007. 1. 1: Replaces leading zeros with spaces as place holders. o 2007.1.1: Prints month and day with no leading zero or space.
DT TRIM is not available when MX SIZE is set to 3.
Total Count
Total count shows how many times the photo eye has triggered printing since the last time the count was reset. The count can be reset here by selecting YES and pressing ↵.
Init Data
The INIT DATA function ERASES ALL DATA except TOTAL COUNT and S/N. Once this is done any lost data cannot be recovered.
To initialize all data:
1.Press STUP key
2.Select INIT DATA and press ↵.
3.Select Yes and press ↵.
Extend
The EXTEND sub menu contains advanced printing and setup functions that change the way the QM2 prints.
∙RPEAT JET:
oREPEAT: Sets the number of times the message is repeated. “CONTINUE” repeats the
message while the photo eye is activated.
oINTERVAL: Not used.
oS/N COUNT: “COUNT” changes the serial number each time the message is printed. “HOLD” changes the serial number with each activation of the photo eye.
MSSC, LLC Collinsville, IL USA Tel:
www.msscllc.com