Replacing, moving, or adding hard drives
In this section |
|
Identifying the status of a hard drive......................................................................................................... | |
Recognizing hard drive failure................................................................................................................. | |
Replacing hard drives............................................................................................................................. | |
Moving drives and arrays ....................................................................................................................... | |
Adding drives ........................................................................................................................................ |
Identifying the status of a hard drive
When a drive is configured as a part of an array and connected to a
Item Description
1Fault/UID LED (amber/blue)
2Online LED (green)
Online/activity LED | Fault/UID LED | Interpretation |
|
(green) | (amber/blue) |
|
|
|
|
|
|
On, off, or flashing | Alternating amber | The drive has failed, or a predictive failure alert has been |
|
| and blue | received for this drive; it also has been selected by a |
|
|
| management application. |
|
|
|
|
|
On, off, or flashing | Steadily blue | The drive is operating normally, and it has been selected by a |
|
|
| management application. |
|
|
|
|
|
On | Amber, flashing | A predictive failure alert has been received for this drive. |
|
| regularly (1 Hz) | Replace the drive as soon as possible. |
|
|
|
| |
|
|
|
|
On | Off | The drive is online, but it is not active currently. |
|
|
|
|
|
|
| Replacing, moving, or adding hard drives 26 |