Replacing, moving, or adding hard drives
In this section | 
  | 
Identifying the status of a hard drive  | 26  | 
Recognizing hard drive failure  | 27  | 
Replacing hard drives  | 29  | 
Moving drives and arrays  | 32  | 
Adding drives  | 32  | 
Identifying the status of a hard drive
When a drive is configured as a part of an array and connected to a 
Item  | Description  | 
1Fault/UID LED (amber/blue)
2Online LED (green)
Online/activity LED  | Fault/UID LED  | Interpretation  | 
(green)  | (amber/blue)  | 
  | 
  | 
  | 
  | 
On, off, or flashing  | Alternating amber  | The drive has failed, or a predictive failure alert has been  | 
  | and blue  | received for this drive; it also has been selected by a  | 
  | 
  | management application.  | 
  | 
  | 
  | 
On, off, or flashing  | Steadily blue  | The drive is operating normally, and it has been selected by a  | 
  | 
  | management application.  | 
  | 
  | 
  | 
On  | Amber, flashing  | A predictive failure alert has been received for this drive.  | 
  | regularly (1 Hz)  | Replace the drive as soon as possible.  | 
  | 
  | |
  | 
  | 
  | 
On  | Off  | The drive is online, but it is not active currently.  | 
  | 
  | 
  | 
Replacing, moving, or adding hard drives 26