You could do the following:

Set the severity level to critical and major by clicking the Custom button next to the Show Severity field.

Type WickedWitch in the Summary Text or Element Name field.

Once you set all of your filters, you would click the Apply Filters button.

Selecting a Severity Level

You can filter the events, so you only view events that are of a specified severity level. For example, you can specify that Event Manager displays only events with a Critical severity level.

To select a severity level, select an option from the Show Severity drop-down menu in Event Manager. Then, click the Apply Filters button. The definition for each severity level varies according to the type of element.

IMPORTANT: Events marked as “Clear” are not displayed if you select a severity level other than Clear or All.

Table 69 Severity Levels

Severity Level

Description

 

 

Clear

The event has been marked as cleared.

 

 

Unknown

The event does not fall into the other

 

categories and further information can not

 

be obtained from it.

 

 

Informational

Provides informational data. For example,

 

for Brocade switches it could be a list of

 

switches that have successfully completed

 

firmware download.

 

 

Warning

Provides warning data. For example, for a

 

Brocade switch one or more new physical

 

fabric objects (device port, switch, or fabric)

 

have appeared.

 

 

Minor

Provides a message to indicate a minor

 

problem. For example, for a Brocade switch

 

a physical fabric object (switch port or

 

fabric) has changed state.

 

 

Major

Provides a message to indicate a major

 

problem. For example, for a Brocade switch

 

one or more physical fabric objects (device

 

port, switch, or fabric) have disappeared.

 

 

Storage Essentials 5.00.01 User Guide 421