Removal and Replacement Procedures

17

The blower begins operating immediately.

The power supply/blower assembly LED is green.

Hot-Plug Power Supply

Observe the following conditions for AC power supplies:

CAUTION: Removing a power supply significantly changes the airflow within the chassis. The storage system will shut down to prevent overheating unless the power supply is replaced within

5 minutes.

CAUTION: Handle the blower carefully to avoid damaging the housing:

Do not press on the center section of the blower because this action can damage the blades. Press only on the outer edge of the blower.

Do not rest the power supply on the blower because the weight of the power supply can damage the blower housing.

To remove the component:

1.Disconnect the power cord from the power supply.

2.Remove the blower ("Blower" on page 16).