42 HP MSA 500 G2 Storage System Maintenance and Service Guide

 

 

 

Item

 

LED Description

Status

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

Online status

On = Drive is part of an array and is

 

 

 

 

 

 

 

 

currently working.

 

 

 

 

 

 

 

 

Flashing = Drive is actively online.

 

 

 

 

 

 

 

 

Off = Drive is offline.

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

Fault status

On = Drive failure

 

 

 

 

 

 

 

 

Flashing = Fault-process activity

 

 

 

 

 

 

 

 

Off = No fault-process activity

 

 

 

 

 

 

 

 

 

 

Hot-Plug SCSI Hard Drive LED Combinations

 

 

 

 

 

 

 

 

Activity

Online

Fault LED

Interpretation

 

 

 

LED (1)

LED (2)

(3)

 

 

 

 

 

 

 

 

 

On, off, or

On or off

Flashing

A predictive failure alert has been received for this drive.

 

flashing

 

 

 

 

Replace the drive as soon as possible.

 

 

 

 

 

 

 

 

 

 

 

 

On, off, or

On

Off

The drive is online and is configured as part of an array.

 

flashing

 

 

 

 

If the array is configured for fault tolerance and all other drives in the

 

 

 

 

 

 

 

 

 

 

 

 

array are online, and a predictive failure alert is received or a drive

 

 

 

 

 

 

capacity upgrade is in progress, you may replace the drive online.

 

 

 

 

 

 

On or

Flashing

Off

Do not remove the drive. Removing a drive may terminate the

 

flashing

 

 

 

 

current operation and cause data loss.

 

 

 

 

 

 

The drive is rebuilding or undergoing capacity expansion.

 

 

 

 

 

 

On

Off

Off

Do not remove the drive.

 

 

 

 

 

 

The drive is being accessed, but (1) it is not configured as part of an

 

 

 

 

 

 

array; (2) it is a replacement drive and rebuild has not yet started; or

 

 

 

 

 

 

(3) it is spinning up during the POST sequence.

 

 

 

 

 

 

Flashing

Flashing

Flashing

Do not remove the drive. Removing a drive may cause data loss

 

 

 

 

 

 

in non-fault-tolerant configurations.

 

 

 

 

 

 

Either (1) the drive is part of an array being selected by an array

 

 

 

 

 

 

configuration utility; (2) Drive Identification has been selected in

 

 

 

 

 

 

HP SIM; or (3) drive firmware is being updated.

 

 

 

 

 

 

Off

Off

On

The drive has failed and has been placed offline.

 

 

 

 

 

 

You may replace the drive.