Diagnostics database archiving guide

database. Once the total number of pages held by the evweb DB exceeds this value, history management will move events from the current database to the history database such that the size of the current database reduces by approximately 15-20%.

6.DBRecordLifeTime (evweb DB) - Argument is NUMBER OF DAYS: Indicates the maximum number of days an event should be kept in the current database before moving it into the history database. As Max hold Time is 7 days, 10 days would be sufficient. Events will be moved from current database to history database based on either Max number of pages the DB can hold or DBRecordLifeTime criteria, whichever is met first.

7.ArchedRecordLifetime (evweb_history) - Argument is NUMBER OF DAYS: Indicates the number of days that the events kept in the history database before deleting them permanently.

8