Using the Command Line Interface

/raid10—Reconfigure the array into a RAID 10 (stripe of mirrors).

/restart—Restart reconfiguring the array. /stripe—Reconfigure the array into a RAID 1. /volume—Reconfigure the array into a volume.

/wait—If specified, waits for reconfiguration to complete before returning.

container release_cache {container}

Releases the controller’s cache buffers.

Parameters

{container}—Specifies the ID number of the array on which to release cache buffers.

container remove failover {container} {scsi_device} [{scsi_device}...]

Removes one or more failover disks.

Parameters

{container}—ID of the array whose assigned failover disk(s) to remove.

{scsi_device}—ID for the SCSI device to remove as a failover disk(s).

{scsi_device}...—ID(s) for any other SCSI device(s) to remove as a failover disk.

container remove global_failover {scsi_device} [{scsi_device}...]

Removes a global failover assignment.

Parameters

{scsi_device}—ID for the SCSI device to remove as a failover disk.

{scsi_device}...—ID(s) for any other SCSI device(s) to remove as a failover disk(s).

4-25