Using the Command Line Interface
/raid10—Reconfigure the array into a RAID 10 (stripe of mirrors).
/restart—Restart reconfiguring the array. /stripe—Reconfigure the array into a RAID 1. /volume—Reconfigure the array into a volume.
/wait—If specified, waits for reconfiguration to complete before returning.
container release_cache {container}
Releases the controller’s cache buffers.
Parameters
{container}—Specifies the ID number of the array on which to release cache buffers.
container remove failover {container} {scsi_device} [{scsi_device}...]
Removes one or more failover disks.
Parameters
{container}—ID of the array whose assigned failover disk(s) to remove.
{scsi_device}—ID for the SCSI device to remove as a failover disk(s).
{scsi_device}...—ID(s) for any other SCSI device(s) to remove as a failover disk.
container remove global_failover {scsi_device} [{scsi_device}...]
Removes a global failover assignment.
Parameters
{scsi_device}—ID for the SCSI device to remove as a failover disk.
{scsi_device}...—ID(s) for any other SCSI device(s) to remove as a failover disk(s).