The following rules apply to migration:

1The capacity of the new array must match or exceed the capacity of the current array.

2If the capacity and/or RAID type of the new array requires greater total drive capacity than the current array, the additional capacity must be on drives that are not already used in the current array.

To modify an array:

1Click Modify.

2Select the array that you wish to modify.

3Select the RAID level that you want to migrate the array to, or if you want to expand the capacity of the existing array, select the current RAID level.

Optionally, click Advanced to select the stripe size you want the new array to use, or that you want to change the existing array to.

4If necessary, select the additional drive(s) required for capacity expansion, or necessary to support the new RAID level.

Optionally, click Advanced to adjust the priority for the task.

5Click Finish.