Adaptec SCSI RAID 2120S/2200S Software User’s Guide

container restore RAID5 {container}

Tries to restore a RAID 5 that has a number of dead segments as members.

Parameters

{container}—ID of the RAID 5 to restore.

container scrub [/io_delay{=integer}] [/no_repair{=boolean}] [/wait{=boolean}] {container}

Checks and repairs the consistency of a redundant array (for example, RAID 5 or mirrors).

Parameters

{container}—ID of the redundant array to build.

Switches

/io_delay—Number of milliseconds the controller waits between I/Os when building the array.

/no_repair—Specifies whether the build operation be performed without repairing the error.

/wait—Specifies whether the build operation be performed synchronously or asynchronously.

container set cache

[/read_cache_enable{=boolean}] [/unprotected{=boolean}] [/write_cache_enable{=boolean}] {container}

Sets cache parameters for a specific array. Useful only if a native operating system's file system resides on the array.

Parameters

{container}—Specifies the ID of the array on which to set cache parameters.

Switches

/read_cache_enable—Specifies whether to enable the read-ahead cache.

/unprotected—Specifies whether to set the container's NVRAM write-back cache to disable, enable when protected, or enable always. Use this switch in conjunction with the /write_cache_enable switch.

4-26