Adaptec SCSI RAID 2120S/2200S Software User’s Guide
container restore RAID5 {container}
Tries to restore a RAID 5 that has a number of dead segments as members.
Parameters
{container}—ID of the RAID 5 to restore.
container scrub [/io_delay{=integer}] [/no_repair{=boolean}] [/wait{=boolean}] {container}
Checks and repairs the consistency of a redundant array (for example, RAID 5 or mirrors).
Parameters
{container}—ID of the redundant array to build.
Switches
/io_delay—Number of milliseconds the controller waits between I/Os when building the array.
/no_repair—Specifies whether the build operation be performed without repairing the error.
/wait—Specifies whether the build operation be performed synchronously or asynchronously.
container set cache
[/read_cache_enable{=boolean}] [/unprotected{=boolean}] [/write_cache_enable{=boolean}] {container}
Sets cache parameters for a specific array. Useful only if a native operating system's file system resides on the array.
Parameters
{container}—Specifies the ID of the array on which to set cache parameters.
Switches
/read_cache_enable—Specifies whether to enable the read-ahead cache.
/unprotected—Specifies whether to set the container's NVRAM write-back cache to disable, enable when protected, or enable always. Use this switch in conjunction with the /write_cache_enable switch.