Beep Code

Message

Description

(None)

RAM ERROR AT LOCATION xxxxxx :

RAM failed during memory test at the indicated

 

WROTE : xxxx

location.

 

READ : xxxx

 

(None)

PARITY ERROR AT UNKNOWN

Parity error during memory test at unknown

 

LOCATION

location.

(None)

PARITY ERROR AT LOCATION xxxxxx

Parity error during memory test at the indicated

 

 

location.

(None)

NO INTERRUPTS FROM TIMER 0

Timer 0 of the clock timer controller does not

 

 

generate system interrupts correctly.

(None)

UNEXPECTED AMOUNT OF MEMORY -

System memory size does not match the CMOS

 

RUN SCU

record.

(None)

CLOCK NOT TICKING CORRECTLY

System clock does not work correctly.

(None)

TIME/DATE CORRUPT - RUN SCU

Time/date information in CMOS is invalid.

(None)

MACHINE IS LOCKED - TURN KEY

Keyboard operation is locked.

(None)

BOOT SECTOR 0 HAS CHANGED

Hard disk boot sector has been changed, probably

 

 

because of a virus attack.

(None)

Suspend-to-Disk partition MISSING!

No Suspend-to-Disk partition found.

(None)

Hard Disk ERROR!

Access to the Suspend-to-Disk partition failed.

(None)

Suspend-to-Disk partition signature NOT

No Suspend-to-Disk partition signature found.

 

FOUND!

 

(None)

Suspend-to-Disk partition size TOO

Suspend-to-Disk partition has insufficient capacity.

 

SMALL!

 

(None)

MEMORY SIZE HAS CHANGED --

Memory size has changed after previous Suspend-

 

REBOOTING

to-Disk operation.

Sycard PCCtest 450/460 CardBus Card (Optional)

The PCCtest 450 and 460 CardBus Cards (version 1.05) available from Sycard Technology are the only recommended diagnostic tool that tests the functionality of the PCMCIA slots using a PCMCIA card. Each is a Type II PC Card that works with compatible test software to exercise PCMCIA functions. (For details, see the Sycard Technology Web site: http://www.sycard.com.)

The PCCtest product contains these components:

PCCtest 450 or 460 (revision 1.05) PC Card.

PCCtest 450/460 test software disk. (Software updates are available at the Sycard Technology web site: http://www.sycard.com.)

Configuration headers (PC Card/16-bit and CardBus/32-bit) that attach to the card.

You will also need a CardBus extender card (such as the Sycard PCCextend 70) to avoid wear on the Sycard PCMCIA connector.

The Sycard PCCtest 450 and 460 provide the following tests. See the Sycard documentation for details about running the tests.

Table 3-4. Sycard PCCtest Commands

 

Slot

PCMCIA PC Card (16-bit) test

CardBus (32-bit) test

 

 

(PC Card configuration header)

(CardBus configuration header)

zt1100/xz200/xt1500

N/A

PCT450 -bc1b -0 -v

TESTCB -b92b -0 –v

(technology code IC)

 

 

 

3-26 Troubleshooting and Diagnostics

Technology Code IC)