HUAWEI ME909 Series Mini PCIe Module

 

Hardware Guide

Electrical and Reliability Features

5.3 Operating and Storage Temperatures and Humidity

Table‎ 5-2lists the operating and storage temperatures and humidity for the ME909 module.

Table 5-2Operating and storage temperatures and humidity for the ME909 module

Specification

Min.

Max.

Unit

 

 

 

 

Normal working temperatures[1]

–20

+60

°C

 

 

 

 

Ambient temperature for storage

–40

+85

°C

 

 

 

 

[1]: When the ME909 module works at this temperature, all its RF indexes comply with the 3GPP TS 45.005 and 3GPP TS 34.121-1 specifications.

5.4 Electrical Features of USIM

Table 5-3Electrical features of Digital Pins in the I/O supply domain of the USIM

Interface

Parameter

Description

Minimum Value

Maximum Value

Unit

 

 

 

 

 

VIH

Logic high-level

0.65 x VDD_PX

VDD_PX + 0.3

V

 

input voltage

 

 

 

 

 

 

 

 

VIL

Logic low-level

–0.3

0.35 x VDD_PX

V

 

input voltage

 

 

 

 

 

 

 

 

VOH

Logic high-level

VDD_PX–0.45

VDD_PX

V

 

output voltage

 

 

 

 

 

 

 

 

VOL

Logic low-level

0

0.45

V

 

output voltage

 

 

 

 

 

 

 

 

5.5 Electrical Features of Application Interfaces

Table‎ 5-4lists electrical features (typical values).

Table 5-4Electrical features of application interfaces

 

Parameter

 

 

Description

Minimum Value

 

Maximum Value

 

Unit

 

 

 

 

 

 

 

 

 

 

 

VIH

 

 

Logic high-level

0.65 x VDD_PX

 

VDD_PX + 0.3

 

V

 

 

 

 

input voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Huawei Proprietary and Confidential

 

35

Issue 0.1 (2013-06-09)

 

 

Copyright © Huawei Technologies Co., Ltd.

 

 

 

 

Page 35
Image 35
Huawei ME909 Operating and Storage Temperatures and Humidity, Electrical Features of Usim, Specification Min Max Unit