HUAWEI ME909 Series Mini PCIe Module

 

Hardware Guide

 

RF Specifications

 

 

 

 

 

Operating Band

Tx

Rx

 

 

 

 

 

LTE Band V

824 MHz–849 MHz

869 MHz–894 MHz

 

 

 

 

 

LTE Band VIII

880 MHz–915 MHz

925 MHz–960 MHz

 

 

 

 

 

LTE Band VII

2500 MHz–2570 MHz

2620 MHz–2690 MHz

 

 

 

 

 

LTE Band XX

832 MHz–862 MHz

791 MHz–821 MHz

 

 

 

 

 

GPS L1

-

1574.42 MHz–1576.42 MHz

 

 

 

 

 

GLONASS

-

1597.55 MHz–1605.89 MHz

 

 

 

 

4.3 Conducted RF Measurement

4.3.1Test Environment

Test instrument R&S CMU200, R&S CMW500 ,Agilent E5515C

Power supply

Keithley 2303, Agilent 66319

RF cable for testing L08-C014-350 of DRAKA COMTEQ or Rosenberger

Cable length: 29 cm

The compensation for different frequency bands relates to the cable and the test environment.

The instrument compensation needs to be set according to the actual cable conditions.

4.3.2Test Standards

Huawei modules meet 3GPP TS 51.010-1, 3GPP TS 34.121-1 and 3GPP TS 36.521-1 test standards. Each module passes strict tests at the factory and thus the quality of the modules is guaranteed.

4.4 Conducted Rx Sensitivity and Tx Power

4.4.1Conducted Receive Sensitivity

The conducted receive sensitivity is a key parameter that indicates the receiver performance of ME909u-521 module. The conducted receive sensitivity refers to the weakest signal that the module at the antenna port can receive. The BER must meet the 3GPP protocol requirements in the case of the minimum signal.

 

Huawei Proprietary and Confidential

26

Issue 0.1 (2013-06-09)

Copyright © Huawei Technologies Co., Ltd.

 

Page 26
Image 26
Huawei ME909 manual Conducted RF Measurement, Conducted Rx Sensitivity and Tx Power, Test Environment, Test Standards