Huawei ME909u-521 manual ECM Application Scenarios, ECM Dialing, Reference Process

Models: ME909u-521

1 67
Download 67 pages 9.88 Kb
Page 21
Image 21
4 ECM Application Scenarios

HUAWEI ME909u-521 LTE LGA Module

 

Application Guide

ECM Application Scenarios

4 ECM Application Scenarios

4.1 ECM Dialing

4.1.1 Reference Process

Command

Description

 

 

AT^NDISDUP=?

Check the parameter range supported by

 

the command.

 

 

^NDISDUP: (1-16),(0-1)

 

OK

 

 

 

AT^NDISDUP=1,1,"1234"

Set up a dial-up connection using the

 

APN provided by the network server.

 

 

OK

The command is successfully executed.

^NDISSTAT: 1,,,"IPV4"

Report the dial-up connection state.

 

 

AT^NDISDUP=1,1,"4321","huawei",

Set up a dial-up connection using the

"huawei",1

account, password, and authentication

 

mode provided by the network server.

 

 

OK

The command is successfully executed.

^NDISSTAT: 1,,,"IPV4"

Report the dial-up connection state.

 

 

The process of obtaining the IP address:

1.After the dial-up is successful, the module will establish the DHCP service automatically.

2.The PC driver will get the dial-up state and send net_ready state to the network manage.

3.The network manage sends the DHCP service discover.

Issue 01 (2013-07-05)

Huawei Proprietary and Confidential

21

Copyright © Huawei Technologies Co., Ltd.

 

 

Page 21
Image 21
Huawei ME909u-521 manual ECM Application Scenarios, ECM Dialing, Reference Process