Hubbell Electric Heater Company HE, HSE manual Heating Element, Disconnect power from unit

Models: HSE HE

1 22
Download 22 pages 19.05 Kb
Page 15
Image 15
Manual background

HEATING ELEMENT

1.Disconnect power from unit.

2.Shut off incoming water supply.

3.Attach hose to drain connection.

4.Lift manual release lever on relief valve to let air into system or break union on outgoing water line.

5.Drain water from tank.

6.Disconnect the wires from the heating element terminals.

7. Remove the 3/8-16 nuts.

Tank Flange

Element Terminals

 

Nuts

8. Withdraw element assembly and remove gasket. Gasket Manual background

Element Assembly

9.Install new gasket and insert new heating element.

10.For 3-phase heaters, rewire the element according to the voltage and phase rating of the unit as shown below. For single phase operations, connect wires to terminals.

11.Fill tank and check around gasket for any leaks.

15

Page 15
Image 15
Hubbell Electric Heater Company HE, HSE manual Heating Element, Disconnect power from unit