PAGE 11 of 14

MODEL TI984 TELEPHONE INTERFACE

42004-071F

 

 

 

Programming Table

 

 

 

 

Function

RESET UNIT TO FACTORY CODES (DEFAULT)

 

 

KEY SEQUENCE

# #

 

 

DESCRIPTION

Voice access method (for incoming calls)

(Day Mode)

7-second voice page

 

60 seconds after the page for the call to be answered before disconnection

 

Auto-connect enabled

 

4 incoming rings before TI984 enters page mode

 

7 second hang up delay

 

Internal Day/Night switch

 

 

DESCRIPTION

Ring access method (for incoming calls)

(Night Mode)

1 incoming ring before TI984 generates a ring tone on the page line

 

7 second hang up delay

 

Internal Day/Night switch

 

 

*Function

SELECT INCOMING CALL - MANUAL ACCESS METHOD

 

 

KEY SEQUENCE

# 3 3

 

 

DESCRIPTION

If selected, a switchboard operator must manually connect the telephone call to the

 

Page/Party® system by pressing the ACCESS button on the front cover of the TI984.

 

The incoming call is automatically transferred to the designated party line, provided

 

a station is off-hook on the designated party line.

 

 

*Function

SELECT INCOMING CALL - VOICE ACCESS METHOD

 

 

KEY SEQUENCE

# 3 0 P P M M A

 

 

DESCRIPTION

If selected, incoming calls are transferred directly to page line.

 

PP = number of seconds of voice page (00 to 99)

 

MM = number of seconds after a page that the call must be answered (00 to 99) or

 

the call is disconnected (auto-connect DISABLED).

 

With auto-connected ENABLED, the call is transferred directly to the

 

designated party line after the page, provided the designated party line is in use.

 

A = auto-connect option: 1 to enable or 0 to disable

 

Example: To set a 15-second voice page, a 25-second period after the end of the

 

page before the call reverts to the auto-connect option, and to enable the auto-

 

connect option, enter the following code: # 3 0 1 5 2 5 1

 

 

*Function

SELECT INCOMING CALL - RING ACCESS METHOD

 

 

KEY SEQUENCE

# 3 1

 

 

DESCRIPTION

If selected, incoming calls are transferred directly to the page line after a

 

programmed number of rings have elapsed. To answer the call, someone must take

 

a Page/Party® station off-hook on the designated party line.

 

 

f:\standard ioms - current release\42004 instr. manuals\42004-071f.doc

05/03

Page 12
Image 12
Hubbell Electric Heater Company TI984 operating instructions Programming Table