PAGE 2 of 14

MODEL TI984 TELEPHONE INTERFACE

42004-071F

 

 

WARNING

This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual, may cause interference to radio communications. It has been tested and found to comply with the limits for a Class “A” computing device pursuant to Subpart J or Part 15 of the FCC Rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of the equipment in a residential area is likely to cause interference. If interference occurs, the user, at their own expense, will be required to take whatever measures are necessary to correct this interference.

Installation

WARNING

This device can present a 115/230 V ac shock hazard. Please use care when handling this device. Be sure that the ac power is not connected during wiring.

Site Requirements

The Model TI984 should be mounted near both the GAI-Tronics Page/Party® system and the RJ11C receptacle from the telephone company or Private Branch Exchange (PBX). The distance from the TI984 to one Page/Party® station should be such that someone can adjust the controls on the TI984 while listening to the handset of the station. The distance from the RJ11C receptacle should be less than 14 feet, to allow the use of the supplied plug-in cable.

Note: If there are no handset stations, contact the GAI-Tronics Field Service Department for instructions at 800-492-1212, 8 a.m. to 4:30 p.m., Monday through Friday, Eastern Standard Time (EST).

The TI984 should be installed in an environment within the temperature range of 0º C to +70º C (+32º F to +158º F).

Install the TI984 away from equipment that could cause excessive electrostatic, or electromagnetic interference, or equipment that produces high voltage.

Wiring Instructions

1.Remove the front cover by loosening the 4 captive screws and swinging the cover open to the left. Disconnect the ribbon cable and the telephone cable, and pull the hinges out of the holes in the rear enclosure.

2.Determine which of the 4 available conduit locations is to be used. Drill spots have been provided for use with either a chassis punch or hole saw.

f:\standard ioms - current release\42004 instr. manuals\42004-071f.doc

05/03

Page 3
Image 3
Hubbell Electric Heater Company TI984 operating instructions Installation, Site Requirements, Wiring Instructions