Roberts Gorden BH-60, BH-40, BH-150, BH-175, BH-115, BH-100, BH-140, BH-200, BH-80 Heater Installation

Models: BH-125 BH-80 BH-200 BH-140 BH-100 BH-115 BH-175 BH-150 BH-40 BH-60

1 70
Download 70 pages 23.9 Kb
Page 20
Image 20
SECTION 6: HEATER INSTALLATION

BH-SERIES INSTALLATION, OPERATION AND SERVICE MANUAL

SECTION 6: HEATER INSTALLATION

Manual backgroundWARNING

Severe Injury Hazard

Secure burner to burner tube with bolts and lockwashers.

Hang heater with materials with a minimum working load of 75 lbs (33 kg).

Failure to follow these instructions can result in death, injury or property damage.

Expansion and contraction of the tube dictates that the minimum suspension lengths must be maintained. See table on Page 15, Figure 14.

Manual backgroundWARNING

Cut/Pinch Hazard

Wear protective gear during installation, operation and service.

Edges are sharp.

Failure to follow these instructions can result in injury.

To ensure your safety and comply with the terms of the warranty, all units must be installed in accordance with these instructions.

The gas or the electrical supply lines must not be used to support the heater.

Do not locate the gas or electric supply lines directly over the path of the flue products from the heater. The heater must be installed in a location that it is readily accessible for servicing.

The heaters must be installed in accordance with clearances to combustibles as indicated on the rating plate and in this instruction manual.

The minimum and maximum gas inlet pressures

must be maintained as indicated on the rating plate. Typical installation configurations are shown on Page 15, Figure 14.

14 of 59

Page 20
Image 20
Roberts Gorden BH-60, BH-40, BH-150, BH-175, BH-115, BH-100, BH-140, BH-200, BH-80, BH-125 service manual Heater Installation