| PAGE 12 of 14 |
MODEL TI984 TELEPHONE INTERFACE | |
|
|
| Programming Table |
|
|
|
|
*Function | SELECT INCOMING CALL - SELECTIVE ACCESS METHOD |
|
|
KEY SEQUENCE | # 3 2 P P M M A X Y |
|
|
DESCRIPTION | If selected, incoming calls receive a coded beep to indicate if the designated party |
| line is in use. After hearing the coded beeps, the caller can select either voice |
| access method or ring access method. Refer to Selective Access Method on page 8. |
| PP = number of seconds of voice page (00 to 99) |
| MM = number of seconds after the page that the call must be answered (00 to 99); |
| if call is not answered, it is terminated. |
| A = |
| X = access code digit for caller to select voice access method (0 to 9) |
| Y = access code digit for caller to select ring access method (0 to 9, must be |
| different than X) |
| Example: To set a |
| page before the call reverts to the |
| option, to set the code to enter voice access method at 2, and to set the code to enter |
| page access method at 5, enter the following code: # 3 2 1 5 2 5 1 2 5 |
|
|
Function | SET NUMBER OF INCOMING RINGS |
|
|
KEY SEQUENCE | # 4 N |
|
|
DESCRIPTION | Sets the number of rings that must elapse before the TI984 acknowledges an |
| incoming call. This function provides time for an operator to intercept incoming |
| calls. Example: To set the incoming ring delay at 4 rings, enter the following code: |
| # 4 4. The TI984 then answers the call after the fifth ring. |
|
|
Function | SET HANG UP DELAY |
|
|
KEY SEQUENCE | # 9 N N |
|
|
DESCRIPTION | NN is the number of seconds (00 to 99) that elapse after all Page/Party® stations on |
| the designated party line are |
| explained above, this time should not be set to zero in case users want to page |
| during the conversation. The average time for this delay should be around 7 |
| seconds. To program a |
|
|
Function | SET DAY/NIGHT SWITCH (INTERNAL/EXTERNAL) |
|
|
KEY SEQUENCE | # 8 X |
|
|
DESCRIPTION | Sets the method of switching between day and night modes. If the front panel |
| Day/Night switch is to be used, select INTERNAL. If the selection is made using a |
| remote switch, select EXTERNAL. Example: |
| To select internal Day/Night switching, enter: # 8 1. |
| To select external Day/Night switching, enter: # 8 0 |
|
|
*Choose only one of these functions for each mode: one for Day mode and one for Night mode.
f:\standard ioms - current release\42004 instr.
05/03