PAGE 12 of 14

MODEL TI984 TELEPHONE INTERFACE

42004-071F

 

 

 

Programming Table

 

 

 

 

*Function

SELECT INCOMING CALL - SELECTIVE ACCESS METHOD

 

 

KEY SEQUENCE

# 3 2 P P M M A X Y

 

 

DESCRIPTION

If selected, incoming calls receive a coded beep to indicate if the designated party

 

line is in use. After hearing the coded beeps, the caller can select either voice

 

access method or ring access method. Refer to Selective Access Method on page 8.

 

PP = number of seconds of voice page (00 to 99)

 

MM = number of seconds after the page that the call must be answered (00 to 99);

 

if call is not answered, it is terminated.

 

A = auto-connect option: 1 to enable or 0 to disable

 

X = access code digit for caller to select voice access method (0 to 9)

 

Y = access code digit for caller to select ring access method (0 to 9, must be

 

different than X)

 

Example: To set a 15-second voice page, a 25-second period after the end of the

 

page before the call reverts to the auto-connect option, to enable the auto-connect

 

option, to set the code to enter voice access method at 2, and to set the code to enter

 

page access method at 5, enter the following code: # 3 2 1 5 2 5 1 2 5

 

 

Function

SET NUMBER OF INCOMING RINGS

 

 

KEY SEQUENCE

# 4 N

 

 

DESCRIPTION

Sets the number of rings that must elapse before the TI984 acknowledges an

 

incoming call. This function provides time for an operator to intercept incoming

 

calls. Example: To set the incoming ring delay at 4 rings, enter the following code:

 

# 4 4. The TI984 then answers the call after the fifth ring.

 

 

Function

SET HANG UP DELAY

 

 

KEY SEQUENCE

# 9 N N

 

 

DESCRIPTION

NN is the number of seconds (00 to 99) that elapse after all Page/Party® stations on

 

the designated party line are on-hook, and the outside call is disconnected. As

 

explained above, this time should not be set to zero in case users want to page

 

during the conversation. The average time for this delay should be around 7

 

seconds. To program a 7-second hang-up delay, enter the following code: # 9 0 7

 

 

Function

SET DAY/NIGHT SWITCH (INTERNAL/EXTERNAL)

 

 

KEY SEQUENCE

# 8 X

 

 

DESCRIPTION

Sets the method of switching between day and night modes. If the front panel

 

Day/Night switch is to be used, select INTERNAL. If the selection is made using a

 

remote switch, select EXTERNAL. Example:

 

To select internal Day/Night switching, enter: # 8 1.

 

To select external Day/Night switching, enter: # 8 0

 

 

*Choose only one of these functions for each mode: one for Day mode and one for Night mode.

f:\standard ioms - current release\42004 instr. manuals\42004-071f.doc

05/03

Page 13
Image 13
Hubbell Electric Heater Company TI984 operating instructions # 3 2 P P M M a X Y