MODEL TI984 TELEPHONE INTERFACE |
Figure 2. Termination Area
Telephone Line Connections
The TI984 should be connected to the Central Office (CO) RJ11C jack from the telephone company or to a PBX with the
The connection outlined in Figure 3 is recommended |
|
because it allows the use of all the available types of |
|
incoming modes. If the call from the CO is to be directly |
|
connected to the Page/Party® system, use the bypass feature |
|
available on the PBX. | Figure 3. Telephone Connections |
|
Power
The unit can be powered by 115 or 230 V ac (50 to 60 Hz), or 24 V dc. If using ac power, connect the ac neutral wire (white) to terminal 6 and the ac hot wire (black) to terminal 2. See Figure 4. The earth ground wire (green or green/yellow stripe) should be connected to terminal 4. Set the Power Selector switch at the lower right of the power supply to the proper voltage setting (115 or 230 V).
Figure 4. Power Connections