White Line Screen

USING THE LEGEND 2000 SERIES

SURFACE CLUTTER / WHITE LINE / FILTER / DEPTH ALARM / TEMP ALARM

White Line

WHITE LINE activates and adjusts a feature which changes how

the LEGEND 2000 SERIES

draws the bottom contour and structure, and also shows fainter sonar returns more clearly.

When a WHITE LINE

setting of 1 to 8 is selected, a light gray band highlights the

strongest sonar returns within the sonar image and makes a distinctive outline along the bottom contour, structure and fish. Selecting a larger numeric setting increases the width of the band and makes fainter sonar returns more noticeable, but the LEGEND 2000’S ability to show subtle differences in bottom composition and structure is reduced. Selecting a smaller numeric setting narrows the band and shows greater variation in bottom composition. Selecting OFF turns the WHITE LINE feature off.

The WHITE LINE setting is retained in memory after the LEGEND 2000 SERIES is turned off. The factory setting is OFF.

Filter

FILTER (DEEP Models only) turns the filtering algorithms on and off.

Select ON to filter excess sonar noise. Select OFF to show the greatest amount of sonar information.

The FILTER setting is retained in memory after the 2000 Deep/2005 Deep is turned off. The factory setting is ON.

Depth Alarm

DEPTH ALARM activates a shallow water depth

alarm. The alarm will

sound when the digital depth becomes equal to or less than the setting. The tone sounds at a rapid rate for several seconds and then sounds intermittently until the boat moves to deeper water. The DEPTH ALARM can be muted by pressing the CONTROL PANEL knob; once muted, the alarm will

not sound again until the boat moves to water deeper than the DEPTH ALARM setting. International models have Depth Alarm settings in metres and fathoms

Note: Remember that depth is measured from the transducer, not from the surface of the water.

The DEPTH ALARM setting returns to factory default after the LEGEND 2000 SERIES is turned off. The factory setting is OFF.

Temp Alarm

Temp Alarm activates an alarm that sounds when the surface water

temperature changes to fall within or outside selected ranges. These temperature boundaries help define bodies of water that are comfortable for and or are feeding zones for fish. Upper and lower temperatures are set depending on the species of fish being sought. Two basic actions can be selected to trigger an alarm, either entering inside a temperature range or exiting – moving outside a temperature range. Both combines Inside and Outside settings, alarming when crossing a temperature boundary. The Temp Alarm can be muted by pressing the Control Panel knob; once muted, the alarm will not sound again until triggered by a new boundary crossing.

The TEMP ALARM setting returns to factory default after the LEGEND 2000 SERIES is turned off. The factory setting is OFF.

Note: You must select a Temp Alarm mode (INSIDE, OUTSIDE, or BOTH), then set the UPPER TEMP and the LOWER TEMP in order for this feature to work.