MAINTENANCE AND WARRANTY
CONTROL PANELS / MAINTENANCE/TROUBLESHOOTING
UNITS also selects the units of measure for boat speed and depth in one of four additional combinations supported by the International Models only:
•METRES/KPH displays depth in metres/speed in kilometres per hour.
•METRES/KTS displays depth in metres/speed in nautical miles per hour.
•FATHOMS/KTS displays depth in fathoms/speed in nautical miles per hour.
•FATHOMS/KPH displays depth in fathoms/speed in kilometres per hour.
The UNITS settings are retained in memory after the unit is turned off.
Language
LANGUAGE (International Models only) selects the language for text used in the CONTROL PANELS and for messages. See the
LEGEND 2005/2005 DEEP Specifications for included languages.
LANGUAGE setting is retained in memory after the LEGEND 2005 /2005 DEEP is turned off. The factory setting is ENGLISH.
MAINTENANCE
Your LEGEND 2000 SERIES is designed to provide years of
Cleaning
If the unit comes into contact with salt spray, simply wipe the affected surfaces with a cloth dampened in fresh water. Do not use a chemical glass cleaner on the lens, as chemicals in the solution may crack the lens.
When cleaning the LCD protective lens, use a chamois and
If your boat remains in the water for long periods of time, algae and other marine growth can reduce the effectiveness of the transducer. Periodically clean the face of the transducer with liquid detergent. Pivoting the transducer up in the bracket may allow better access for inspection or cleaning.
Wetting the Transducer
If your boat remains out of the water for a long period of time, it may take some time to wet the transducer when returned to the water. Small air bubbles can
cling to the surface of the transducer and interfere with proper operation. These bubbles dissipate with time, or you can wipe the face of the transducer with your fingers after the transducer is in the water.
Heat Damage
Never leave the LEGEND 2000 SERIES in a closed car or
TROUBLESHOOTING
Repairs
Do not attempt to repair the LEGEND 2000 SERIES yourself. There are no
Before You Call Customer Support
Many requests for repair received by Techsonic involve units that do not actually need repair. These units are returned “no problem found.” If you have a problem with your LEGEND 2000 SERIES, use the following troubleshooting guide before calling Customer Support or sending your unit in for repair. The LEGEND 2000 SERIES contains several tools that can aid in determining if there is a problem, as well as how to isolate and repair a problem in many cases.
1. Nothing happens when I turn the unit on.
Check the power cable connection at both ends. Be sure the cable is connected correctly to a reliable power
Check the power connection to the LEGEND 2000 SERIES. It is possible to force the power cable connector into the collector plug incorrectly. If the connector is reversed, the unit will not work. Examine the contacts on the back of the unit to ensure there is no corrosion.
Ensure the cables are properly installed into the collector plug and the collector plug is properly seated into the LEGEND 2000 SERIES.
12