TROUBLESHOOTING GUIDE

TROUBLESHOOTING GUIDE

PROBLEM

PROBABLE CAUSE

SOLUTION

1. Nothing happens;

1. Power turned off or fuse blown.

fan does not move.*

2.

Loose wire connections or

 

 

wrong connections.

 

3.

Weak battery in transmitter.

 

4.

Transmitter too far from fan.

 

5.

Transmiter/Receiver switches in wrong position.

*NOTE: If blades will not turn by hand, contact your nearest service representative.

1.Turn power on or replace fuse.

2.Loosen canopy. Check all connections. (Turn power off while checking.)

3.Install new 9V battery.

4.Maximum range is 15-30 feet.

5.Set switches to matching positions.

2.

Noisy operation.

1. Blade irons loosely screwed to motor.

1.

Tighten screws until snug.

 

 

2.

Blade screwed loosely to blade iron.

2.

Tighten screws.

 

 

3.

Blade cracked.

3.

Replace blades.

 

 

4.

Light globe noisy.

4. Adjust globe.

 

 

 

 

 

3.

Excessive wobbling.

1. Unbalanced blades.

1.

Use blade balancing kit. (See Step 8D.)

 

 

2.

Fan too close to vaulted ceiling.

2.

Lower or move fan.

 

 

3.

Loose blades or blade brackets.

3.

Tighten all screws.

 

 

4.

Fan not secure on hanger assembly.

4.

Turn power off. Support fan very carefully.

 

 

 

 

 

Loosen canopy and hang correctly.

When switching from medium to low speed, you may notice some fan wobble. When fan speed stabilizes at low speed, wobble will disappear. If you have checked the above problems and still have trouble, call (901) 745-9222.

Hunter fans have the power to cut your cooling costs up to 40%.

Beat the High Cost of Cooling

e air movement created by a Hunter ceiling fan lets you set your thermostat higher and still stay comfortable. Every degree you raise the thermostat saves up to 7% on energy costs. So, you can cut back on expensive air conditioning...and save up to 40%* on cooling. In winter, your Hunter fan recirculates warm air and saves up to 10%* on heating bills.

*Your savings many vary based on climate, building type and thermostat setting. On average at low speed settings.

Save Energy and Money While Protecting the Environment

Congratulations! You’re saving energy and money while protecting the environment by purchasing this ENERGY STAR qualified Hunter ceiling fan! With this purchase, you are doing your part to protect the environment. In 2010, ENERGY STAR qualified ceiling fans are projected to cut air pollution by more than 500 million pounds!

Your new ceiling fan has earned the ENERGY STAR label because it meets high energy efficiency specifications set by the Environmental Protection Agency (EPA). ENERGY STAR labeled ceiling fans save energy because they have more efficient fan motors and air delivery due to more aerodynamic blade configurations. Ceiling fan models bearing the ENERGY STAR label move air 14 - 20% more efficiently than typical ceiling fan models. For more information on ENERGY STAR visit www.energystar.gov.

HUNTER FAN COMPANY 2500 FRISCO AVENUE MEMPHIS, TN 38114

41597-01 12/21/2002

7

© 2002 Hunter Fan Company™

Page 7
Image 7
Hunter Fan 41597-01 Troubleshooting Guide, Problem, Probable Cause, Solution, Beat the High Cost of Cooling