Step 5-1: Fan Assembly

Step 5-1: Fan Assembly

Low Profile Version

A. Place the canopy on top of the fan so the hole in the bottom of the canopy fits over the adaptor on the top of the fan. See Figure 5. Place the canopy assembly washer inside the canopy with the vertical flange of the washer resting on the inside of the canopy.

ASSEMBLY

 

 

 

 

#8-32 SCREW

 

 

 

 

 

 

 

CANOPY

 

 

 

WASHER

 

 

Step 5-2: Ball Hanging Version ROUND HOLE

ADAPTOR

Figure 5C. Aligning Tab & GrooveTOP OF FAN

Figure 5. Low Profile Version

B. Position the (3) slots in the canopy assembly washer over the (3) threaded holes in the adaptor. See Figure 5.

C. Secure the canopy to the top of the fan using the (3) #8-32 x 7/8 long screws with lock washers. Make certain all screws ae tight. Failure to do so could result in the fan falling.

CAUTION: To ensure proper engagement of the canopy assem- bly screws, the canopy must fit snug against the top of the fan.

CAUTION: Do not lift motor by wires.

D. Being careful not to scratch the canopy finish, hang the fan from the hook in the ceiling plate using the round hole in the top of the canopy. See Figures 5 and 5A.

CEILING PLATE

HOOK

CANOPY

FAN

Figure 5A. Hanging the Fan

Step 5-2: Ball Hanging Version

CAUTION: Do not lift motor by wires.

A. Insert pipe nipple through canopy and feed wires from top of motor through pipe nipple. Screw pipe nipple into fan until tight (at least 4-1/2 turns). The setscrew locking the pipe nipple to motor must be tightened very securely. See Figure 5B. Failure to tighten screw could result in fan falling.

Step 6: Install Remote Control LEAD WIRES

6” MIN.

PIPE

CANOPY

NIPPLE

 

BALL

 

 

SETSCREW

 

(TIGHTEN

PIPE NIPPLE

SECURELY)

 

MOTOR

 

Figure 5B

B. Before hanging the fan from the ceiling plate align and engage the (2) tabs in the bottom of the canopy with the (2) grooves in the hanger ball. See Figure 5C.

GROOVE IN

HANGER BALL

Manual backgroundManual background TAB IN BOTTOM

OF CANOPY

Figure 5C. Aligning Tab & Groove

Using the round hole in the top of the canopy, hang the fan from the hook in the ceiling plate. Make sure both tabs in the canopy remain engaged with the grooves in the ball. Be careful and don’t scratch the finish while hanging the fan. See Figure 5A.

Step 6: Install Remote Control

and Final Wiring

CAUTION: This device complies with part 13 of the FCC rules. Changes or modifications not expressly approved by Hunter Fan Company could void your authority to operate this equipment.

Operation is Subject to the Following Two Conditions:

(1)This device may not cause harmful interference.

(2)This device must accept any interference received, including interference that may cause undesired operation.

NOTE: Use with a fan that incorporates an air gap switch (nor- mal “ON-OFF” wall switch).

WARNING! Maximum fan load is 100 watts; maximum lamp is 240 watts. Do not use any speed control with this product.

41597-01 12/21/2002