Hunter Fan 51023 What to Expect with Your Installation, Standard Downrod, Shorter Downrod, inches

Models: 53111 53110 53109 53108 53107 51024 51059 51022 51060 51015 51014 51023 51061 51062

1 17
Download 17 pages 52.02 Kb
Page 2
Image 2
What to Expect with Your Installation

What to Expect with Your Installation

If you are unfamiliar with wiring, use a qualified electrician.

30 inches

 

from blade tip to

 

nearest wall or

 

obstruction

7 feet

 

 

From bottom

 

edge of blade

www.HunterFan.com 1.888.830.1326 30 inches

Read and Save These Instructions

This product conforms to UL Standard 507.

7 feetRead and Save These InstructionsWARNINGS

w.1 - To reduce the risk of fire, electrical shock, or personal injury, mount fan directly from building structure and/or an outlet box marked acceptable for fan support of 70 lbs (31.8 kg) and use the mounting screws provided with the outlet box.

Must be able to secure the fan to building structure or fan-rated outlet box

You may need a friend to help you.

WARNINGS Know your wiring

Ceilings that are more than 34° will require an angled mounting kit.

See page 3 for details.

to the floor

1 Standard Downrod2 Shorter Downrod Assess location

1 Standard Downrod

for ceilings 8-10 feet high

2 Shorter Downrod

for fans installed close to ceiling

3 Longer Downrod

for ceilings 10 feet or higher

w.2 - To avoid possible electrical shock, before installing or servicing your fan, disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location. If you cannot lock the circuit breakers in the off position, securely fasten a prominent warning device, such as a tag, to the service panel.

w.3 - To reduce the risk of fire, electrical shock, or motor damage, use only Hunter Solid State Speed Controls.

w.4 - To reduce the risk of personal injury, do not bend the blade brackets when installing the blade brackets, balancing the blades, or cleaning the fan. Do not insert foreign objects in between rotating fan blades.

3 Longer DownrodCAUTIONSCAUTIONS

c.1 - All wiring must be in accordance with national and local electrical codes ANSI/NFPA 70. If you are unfamiliar with wiring, use a qualified electrician.

Check box to see

 

fan weight

Assess ceiling angle

Manual background Select a downrod length

2

c.2 - Use only Hunter replacement parts.

M0001-01 • 08/03/12 • © Hunter Fan Company

Page 2
Image 2
Hunter Fan 51023 What to Expect with Your Installation, Standard Downrod, Shorter Downrod, Longer Downrod, Cautions, feet