Hunter Fan 90057, 90056, 90055 manual A160

Models: 90055 90056 90057

1 40
Download 40 pages 31.14 Kb
Page 6
Image 6
A160

A13

Pull wires through the strain relief.

A14

 

 

 

Ground

 

 

 

Black

 

Green

 

 

2 Pin

 

 

A

Bare Copper

 

 

White

 

 

 

 

 

Fan Motor

 

 

 

Black

Main Switch 1 (AC In)

 

 

White

 

 

White

Light

3 Pin

Black

Light

 

 

 

 

 

 

 

*Option

 

 

*Option Fan & Main Light Together

Black

Switch 2 (AC In)

 

 

Connect wires as shown.

A15

 

 

E

G

F

 

Install the wiring cover plate. Make sure all wiring connections are inside the box or under the wiring cover plate.

6

A160

Connect 4” duct and vent to the outside. Tape joints. If ducting does not fit securely, an adapter may need to be purchased.