PROBLEM

CAUSE

CORRECTION

Pressure reading

It is normal for “some”

If there is an excessive

on the regulated

pressure drop to occur.

amount of pressure drop

pressure gauge

 

when the accessory is used,

drops when an

 

adjust the regulator following

accessory is

 

the instructions in the

used.

 

“Description of Operation”

 

 

paragraph in the “Operation

 

 

Section.

 

 

NOTE: Adjust the regulated

 

 

pressure under flow

 

 

conditions (while accessory

 

 

is being used).

Compressor is

Prolonged excessive use of

Decrease amount of air

not supplying

air.

usage.

enough air to

 

Check the accessory air

operate

Compressor is not large

accessories.

enough for air requirement.

requirement. If it is higher

 

 

than the SCFM or pressure

 

 

supplied by your air

 

 

compressor, you need a

 

 

larger compressor.

 

Hole in hose.

Check and replace if

 

 

required.

 

Check valve restricted.

Remove and clean, or

 

 

replace.

 

Air leaks.

Tighten fittings.

 

 

 

Regulator knob

Damaged regulator

Have checked by a Trained

has continuous

 

Service Technician.

air leak.

 

 

 

 

 

Regulator will

Damaged regulator

Have checked by a Trained

not shut off air

 

Service Technician.

outlet.

 

 

 

 

 

 

 

 

17- ENG

D29616

Page 17
Image 17
Husky D29616 manual Pressure reading