PROBLEM

CAUSE

CORRECTION

Excessive tank

Pressure switch does not

Move On/Auto/Off switch to

pressure - safety

shut off motor when

the “OFF” position, if the

valve pops off.

compressor reaches “cut-

unit does not shut off contact

 

out” pressure.

a Trained Service Technician.

 

Pressure switch “cut-out”

Contact a Trained Service

 

too high.

Technician.

 

 

 

 

 

 

 

Air leaks at

Tube fittings are not tight

Tighten fittings where air can

fittings.

enough.

be heard escaping. Check

 

 

fittings with soapy water

 

 

solution. Do Not

 

 

Overtighten.

Air leaks in air

Defective air tank.

Air tank must be replaced.

tank or at air

 

Do not repair the leak.

tank welds.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Do not drill into, weld or

 

 

otherwise modify air tank

 

 

or it will weaken. The tank

 

 

can rupture or explode.

Air leaks

Leaking seal.

Contact a Trained Service

between head

 

Technician.

and valve plate.

 

 

 

 

 

 

 

 

 

 

 

 

 

Air leak from

Possible defect in safety

Operate safety valve

safety valve.

valve.

manually by pulling on ring.

 

 

If valve still leaks, it should

 

 

be replaced.

 

 

 

Knocking Noise.

Possible defect in safety

Operate safety valve

 

valve.

manually by pulling on ring.

 

 

If valve still leaks, it should

 

 

be replaced.

 

 

 

 

 

 

 