„IGNITION COIL AIR GAP INSPECTION

If the gap is not accurate or when installing the coil or rotor, adjust the air gap between the ignition coil and the iron core of the rotor.

Air Gap:

0.40mm (0.35 to 0.45mm) 0.016 in (0.014 to 0.017 in)

(1)Rotor

(2)Ignition coil

„SHOLDER STRAP

If the shoulder strap is damaged it may break during use, thus causing the product to fall and resulting in personal injury. Follow the instructions below to replace the shoulder strap with new one.

Take off the clip from the strap.

Pass the end of the strap through the hanger.

Return the clip to the strap.

IMPORTANT

Make sure that the thick round bar of the clip is in the strap.

If it is attached in the wrong way, it leads to serious personal injury.

F23

F24

Storage

BEFORE STORING THE BLOWER:

1.Drain the fuel tank and push the primer bulb until it becomes empty of fuel.

2.Remove the spark plug and drop a spoonful of 2-cycle oil into the cylider. Crank the engine several time and install the spark plug.

3.Store unit in a dry, dust free place, out of the reach of children.