GENERAL CLEANING TIPS
! CAUTION

OPERATION

On particularly tough stains, use a brush in combination with detergents and high pressure rinsing.

1.Follow manufacturer’s label directions for mixing correct concentrations of soap/detergents. The soap detergent to water ratio through the pump is approximately 10% (1 to 10).

2.Insert the filter end of the clear plastic detergent tube into the detergent container (Models 9030PW and 1335PW).

3.Use the BLACK 65° quick connect spray tip (all models) (See Figure 16).

GENERAL CLEANING TIPS

1.Apply the detergent so that it thoroughly covers the cleaning surface. Apply the detergent from bottom to top to prevent the detergent from sliding down and streaking. Wait a couple of minutes for the detergent to break down the dirt and grime. Use a brush to lightly scrub heavily soiled areas. NEVER allow the detergent to dry on the cleaning surface.

2.Replace black 65° quick connect tip with another color tip.

NEVER replace quick connect tip

! WARNING when gun is triggered.

3. After using detergents, flush the suction system

by placing the detergent suction tube into a bucket of clean water.

5. Cleaning Power

The easiest way to regulate the cleaning power of your pressure washer is by changing the distance from the surface you are cleaning. Begin spraying with a wide fan pattern while standing several feet from the surface. Slowly move closer to the object you are cleaning, adjusting the spray pattern as necessary, until you find the most effective cleaning technique.

NOTE: Some units also may have a pressure adjustment knob on the pump that can adjust the pressure (models 9030PW and 1335PW).

6. Final Rinse

The final rinse should start at the bottom and work upward. Make sure that you thoroughly rinse the surface and that you remove all detergent.

PRESSURE RELIEF

PROCEDURE

To reduce the risk of bodily injury or property damage, ALWAYS follow this procedure whenever spraying is stopped, when work is completed, and before checking or repairing any part of the system.

1.Engage the trigger safety latch.

2.Turn the unit off.

3.Shut off the water supply.

4.Disengage the trigger safety latch and trigger the gun to relieve pressure.

5.Re-engage the trigger safety latch.

6.Before overnight storage, long term storage, or transporting unit, disconnect the water supply and turn off the fuel supply valve.

7.Shutdown

1.Be sure all detergent is flushed from system.

2.Turn the engine OFF.

3Turn the water supply OFF.

4.After the engine and water supply are turned OFF, trigger the gun to depressurize the system.

NEVER turn the water supply

NOTICE off before turning the engine/motor off. Serious damage could occur to the pump and/or engine/motor.

NEVER disconnect the high pressure discharge hose from

the machine while the system is pressurized. To depressurize, turn engine/motor off, turn water supply off and squeeze gun trigger 2-3 times.

5.After each use, when engine has cooled, wipe all surfaces of the pressure washer with a clean, damp cloth.

DO NOT store the pressure washer outdoors.

DO NOT store the pressure washer where it might freeze unless it has been properly winterized.