SAFETY INSTRUCTIONS
Ground fault circuit interrupter (K3000 Wet)
Ground fault circuit interrupters are for protection in case an electrical fault should occur.
The LED indicates that the ground fault circuit interrupter is on and that the machine can be switched on. If the LED is not on, push the RESET button (green).
Check the ground fault circuit interrupter
•Connect the machine to the socket. Push the RESET button (green) and the red LED lights up.
•Start the machine.
•Push the TEST button (blue).
•The ground fault circuit interrupter should trip and the machine switch off instantly. If not, contact your dealer.
•Reset with the RESET button (green).
Cutting blades
WARNING! A cutting blade may burst and
!cause injury to the operator.
Never use a cutting blade at a lower speed rating than that of the power cutter.
Never use a cutting blade for any other purpose than that it was intended for.
General
•Cutting blades are available in two basic designs; abrasive discs and diamond blades.
•
•Make sure that the right bushing is used for the cutting blade to be fitted on the machine. See the instructions under the heading Assembling the cutting blade.
Suitable cutting blades
Cutting blades | K3000 | K3000 Wet |
|
|
|
Abrasive discs | Yes | Yes* |
|
|
|
Diamond blades | Yes | Yes |
|
|
|
Rescue blade | No | No |
|
|
|
*Without water |
|
|
Cutting blades for different materials |
| Concrete | Metal | Plastic |
|
|
|
|
Abrasive discs | X | X | X |
|
|
|
|
Diamond blades | X |
|
|
|
|
|
|
Hand-held, high-speed machines
Our cutting blades are manufactured for
Special blades
Some cutting blades are designed for stationary equipment and for use with attachments.Such cutting blades must not be used on portable power cutters.
Always contact local authorities and make sure you are following applicable directives.
10 – English