SAFETY INSTRUCTIONS

Ground fault circuit interrupter (K3000 Wet)

Ground fault circuit interrupters are for protection in case an electrical fault should occur.

The LED indicates that the ground fault circuit interrupter is on and that the machine can be switched on. If the LED is not on, push the RESET button (green).

Check the ground fault circuit interrupter

Connect the machine to the socket. Push the RESET button (green) and the red LED lights up.

Start the machine.

Push the TEST button (blue).

The ground fault circuit interrupter should trip and the machine switch off instantly. If not, contact your dealer.

Reset with the RESET button (green).

Cutting blades

WARNING! A cutting blade may burst and

!cause injury to the operator.

Never use a cutting blade at a lower speed rating than that of the power cutter.

Never use a cutting blade for any other purpose than that it was intended for.

General

Cutting blades are available in two basic designs; abrasive discs and diamond blades.

High-quality blades are often most economical. Lower quality blades often have inferior cutting capacity and a shorter service life, which results in a higher cost in relation to the quantity of material that is cut.

Make sure that the right bushing is used for the cutting blade to be fitted on the machine. See the instructions under the heading Assembling the cutting blade.

Suitable cutting blades

Cutting blades

K3000

K3000 Wet

 

 

 

Abrasive discs

Yes

Yes*

 

 

 

Diamond blades

Yes

Yes

 

 

 

Rescue blade

No

No

 

 

 

*Without water

 

 

Cutting blades for different materials

 

Concrete

Metal

Plastic

 

 

 

 

Abrasive discs

X

X

X

 

 

 

 

Diamond blades

X

 

 

 

 

 

 

Hand-held, high-speed machines

Our cutting blades are manufactured for high-speed, portable power cutters. If blades from other manufacturers are used, ensure that the blades conform to all regulations and demands that concern this type of power cutter.

Special blades

Some cutting blades are designed for stationary equipment and for use with attachments.Such cutting blades must not be used on portable power cutters.

Always contact local authorities and make sure you are following applicable directives.

10 – English

Page 10