TO CLEAN BATTERY AND TERMINALS Corrosion and dirt on the battery and termi- nals can cause the battery to “leak” power.

1.Disconnect BLACK battery cable first then RED battery cable and remove battery from tractor.

2.Rinse the battery with plain water and dry.

3.Clean terminals and battery cable ends with wire brush until bright.

4.Coat terminals with grease or petro- leum jelly.

5.Reinstall battery (See “REPLACING BATTERY" in the SERVICE AND AD- JUSTMENTS section of this manual).

TRANSAXLE COOLING

The transmission fan and cooling fins should be kept clean to assure proper cooling.

Do not attempt to clean fan or transmis- sion while engine is running or while the transmission is hot. To prevent possible damage to seals, do not use high pressure water or steam to clean transaxle.

Inspect cooling fan to be sure fan blades are intact and clean.

Inspect cooling fins for dirt, grass clip- pings and other materials. To prevent damage to seals, do not use com- pressed air or high pressure sprayer to clean cooling fins.

TRANSAXLE PUMP FLUID

The transaxle was sealed at the factory and fluid maintenance is not required for the life of the transaxle. Should the trans- axle ever leak or require servicing, contact your nearest qualified service center.

V-BELTS

Check V-belts for deterioration and wear after 100 hours of operation and replace if necessary. The belts are not adjustable. Replace belts if they begin to slip from wear.

ENGINE

LUBRICATION

Only use high quality detergent oil rated with API service classification SG-SL. Select the oil’s SAE viscosity grade according to your expected operating temperature.

SAE VISCOSITY GRADES

 

 

 

 

 

 

 

 

 

 

10W30

 

 

 

 

 

 

 

5W-30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F

-20

0

 

 

30 32 40

 

60

 

80

100

C

-30

-20

-10

0

10

20

30

40

TEMPERATURE RANGE ANTICIPATED BEFORE NEXT OIL CHANGE

oil_visc_chart4_e

Change the oil after every 50 hours of op- eration or at least once a year if the tractor is not used for 50 hours in one year.

Check the crankcase oil level before start- ing the engine and after each eight (8) hours of operation.

TO CHANGE ENGINE OIL

Determine temperature range expected before oil change. All oil must meet API service classification SG-SL.

Be sure tractor is on level surface.

Oil will drain more freely when warm.

Catch oil in a suitable container.

1.Remove oil fill cap/dipstick. Be careful not to allow dirt to enter the engine when changing oil.

2.Remove yellow cap from end of drain valve and install the drain tube onto the fitting.

 

Oil Drain Valve

 

 

Closed

 

 

 

and

0

 

63

 

 

4

 

2

 

Locked

Position

Yellow Cap

Drain Tube

3.Unlock drain valve by pushing inward slightly and turning counterclockwise.

4.To open, pull out on the drain valve.

5.After oil has drained completely, close and lock the drain valve by pushing inward and turning clockwise until the pin is in the locked position as shown.

6.Remove the drain tube and replace the cap onto the end of the drain valve.

7.Refill engine with oil through oil fill dip- stick tube. Pour slowly. Do not overfill. For approximate capacity see “PROD- UCT SPECIFICATIONS” section of this manual.

8.Use gauge on oil fill cap/dipstick for checking level. For accurate reading, insert dipstick into the tube and push down firmly into place before removing. Keep oil up to, but not over, the “FULL” line on dipstick. Push dipstick down firmly into the tube when finished.

18

Page 18
Image 18
Husqvarna LOYTH20F42T manual Transaxle Pump Fluid, Engine, Transaxle Cooling, Belts, Lubrication