Hand Held Device | PROTOCOL™ |
|
STATUS MENU
This is a read only menu. It gives you current operating conditions.
P1 gives the present pressure for the suction man- ifold.
P2 gives the second suction pressure input.*
Press ESC Key.
SETPOINT is the Suction Set Point for the control board. The board turns compressors ON and OFF to maintain this suction pressure.
# COMPS - 1 | 2 | 3 4 |
ON(X) | X | X |
lists the compressor numbers, and indicates which are running.
Note: Compressors are configured as follows:
Horizontal Protocols
1 |
| 2 |
| 3 |
| 4 |
| 5 |
| 6 |
|
|
|
|
|
|
|
|
|
|
|
Vertical Protocols
2 4 6
1 3 5
*When Split Suction is installed or when Satellite compressor is controlled by pressure, P2 can also be used to monitor high side discharge pressures.
P/N 374511B
Page 7
PROTOCOL MAIN MENU
STATUS MENU
PRESSURE STATUS |
| |
| P1 | P2 |
SUCTION | 0 | 0 |
SETPOINT | 0 | 0 |
# COMPS - 1 2 3 4
ON(X) X X PRESS ENT FOR MORE
970307 | HUSSMANN CORPORATION • BRIDGETON, MO |