START UP
See the specific merchandiser's Data Sheet Set for
refrigerant settings and defrost requirements.
Bring merchandisers down to the operating
temperatures listed on the data sheet.
Each 4 ft (1219 mm) section has its own evapora-
tor coil and pre-set non-adjustable thermostatic
expansion valve (TEV). No adjustment is
required. DO NOT REMOVE THE CAP ON THE
TEVS.This cap is to be removed only for valve
disassembly.
The TEV has been factory set to provide the
recommended performance settings as specified
on the merchandiser data sheets.
STOCKING
Product should NOT be placed in merchandisers
until case is at proper operating temperature.
Proper rotation of product during stocking is nec-
essary to prevent product loss.
AIR DISCHARGE AND RETURN FLUES MUST REMAIN
OPEN AND FREE OF OBSTRUCTION AT ALL TIMES to
provide proper refrigeration and air curtain
performance. Do not allow product, packages,
signs, etc. to block these grilles. Do not use
non-approved shelving, baskets,display racks, or
any accessory that could hamper air curtain
performance.
LOAD LIMITS
Each merchandiser has a load limit decal.
Recommended load limit profiles are shown on
the next page.
Shelf life of perishables will be short if load limit
is violated. Overstocking will adversely affect
product temperature and merchandiser efficiency.
DO NOT BLOCK AIR GRILLE.

P/N 406928 4-1

EEuurroo DDeellii MMeerrcchhaannddiisseerrss
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 (Printed in U.S.A.)

SSTTAARRTT UUPP // OOPPEERRAATTIIOONN

Removal of the TEVcap will result in
refrigerant loss unless the system is first
isolated and the refrigerant recovered.
CAUTION
!
LOAD LIMIT
At no time should merchandisers be
stocked beyond the load limits indicated.
WARNING
!