![Wiring Diagrams](/images/new-backgrounds/54271/5427125x1.webp)
Griddle
(6) 206W/220VAC Flexible Heater Pad
Overhead Lighting
INCANDESCENT LAMPS
GE APPLIANCE BULB
(6)
(6)
White Red White | White Red White | White Red White |
| Loads, amp | |
| 208 V | 240 V |
L1 | 19.7 | 22.8 |
L2 | 14.2 | 16.4 |
L3 | 0.0 | 0.0 |
|
|
|
Note: Case MUST be grounded
Rev. 0608
Overhead Heating Element
2700 W / 240 VAC
Ledge
13
White Red White | Bulb Sensor | White Red White | White Red White |
Electronic
POWER |
|
|
| P1 |
|
| ||
1 | 2 | 3 | 4 | 5 | 6 | 7 | ||
|
|
|
|
|
|
|
COOLING
FAN
MOTOR
H1 | H2 |
M
P L1 L2
(2) F14T5/TL830
(2) F14T5/TL830
(2) F14T5/TL830
Wiring Diagrams
L1
L2
L |
| Contactor |
| s | |
|
|
SAFETY
LCLOSE ON RISE NGT # 11S31T4444
Pilot
OFF: 80.6°F
(LOCATED IN COLUMN)
L
Pilot Light
SWITCH
L
15 AMP
FUSE
FUSE HOLDER
L
L3
N
G
~208 / 240V - 1 Ø - 60Hz
SWITCH
® | HussmannCorporation | Revisions: |
|
| Drawn By: | D.QUAN | Project Title: | Drawing No.: | |
| 13770 RamonaAvenue | No. | Description: | Date: | By: | Checked By: |
|
| W6100012 |
| Chino, CA. 91710 | 1 | DELETED (1) | 08/05/05 | D.Q. | Date: | 06.12.2000 |
| |
|
|
|
|
| Drawing Title: RHR Hex 4' Case Wiring |
| |||
|
|
|
|
| Next Assembly: | final |
| ||
| Lic.#: 644406 |
|
|
|
| Sheet 1 of 1 | |||
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|