Rev. 0505

Maintenance cont’d

Glass Sweep Installation

(WHERE APPLICABLE)

PARTS LIST

¥Silicone 1200 (or comparable)

¥Masking tap (not supplied)

INSTRUCTIONS

1.Cut a strip of the glass sweep material to the proper length.

2.Open glass wide enough to apply a few small drips of #1200 silicone down the edge of one side of the glass. Space each drop about 4Ó apart.

3.Apply the glass sweep strip to the freshly siliconed end, making sure to align the edges top and bottom. Carefully wipe up any excess silicone that may be bubbling up from the edges.

4.Apply tape across the strip, to hold it in place on edge of glass until the silicone has a chance to properly dry (approximately 30 minutes).

5Repeat process for strip on the other edge.

ELECTRICAL PRECAUTIONS

BEFORE

SERVICING

Always Disconnect Electrical

Power at the Main Disconnect when servicing or replacing any electrical component.

This includes (but not limited to) Fans,

Heaters, Thermostats, and Lights.

ALWAYS DISCONNECT ELECTRICAL POWER AT THE MAIN DISCONNECT WHEN SERVICING OR REPLACING ANY ELECTRICAL COMPONENT. This includes (but not limited to) fans, heaters, thermostats, and lights.

TIPS & TROUBLESHOOTING

BEFORE CALLING FOR SERVICE IF SOMETHING SEEMS WRONG, CHECK THE FOLLOWING:

1.Check electrical power supply to the equipment for connection.

2.Check fixture loading. Overstocking case or blocking airflow will affect itÕs proper operation.

3.If frost is collecting on fixture and/or product, check that Humidity Control is working properly, and that no outside doors or windows are openÑallowing moisture to enter store.

FOR PROMPT SERVICE

When Contacting the Factory regarding problems, Be sure to have the Case MODEL and SERIAL NUMBER Handy.

This Information is on a plate located on the case itself.