HydroSurge 5600 operation manual Trouble Shooting Guide, Problem, Cause, Correction

Models: 5600

1 12
Download 12 pages 24.85 Kb
Page 9
Image 9

Trouble Shooting Guide

Before calling for service, follow the steps below, then MANUALLY REGENERATE your softener.

PROBLEM

 

CAUSE

 

CORRECTION

 

 

 

 

 

1. Softener delivers hard water

A.

Bypass valve is open

A.

Close bypass valve.

 

B.

No salt in brine tank

B.

Add salt to brine tank and maintain salt level

 

 

 

 

above water level.

 

C.

Insufficient water flowing into brine tank

C. Check salt setting and clean brine line flow

 

 

 

 

control if plugged.

 

D.

Salt bridged

D.

Break salt bridging – see page 6.

 

E.

Loose brine line

E.

Tighten connections at control valve and at

 

 

 

 

brine valve.

 

F.

Plugged injector assembly

F.

Clean/replace injectors and screen.

 

 

 

 

 

2. Intermittent soft water

A.

Control will not draw brine properly

A.

Maintain water pressure at 20 psi minimum.

 

 

 

 

Check for restrictions in drain line. Clean or

 

 

 

 

replace injector assembly. Check for air leaks

 

 

 

 

between control valve and air check valve

 

 

 

 

and tighten connections.

 

B. Using hot water during regeneration

B.

Avoid using hot water at this time as water

 

 

cycle

 

heater will fill with hard water.

 

C.

Incorrect salt setting

C.

Adjust salt setting.

 

D.

Softener capacity too small

D.

Increase capacity by replacing with larger

 

 

 

 

unit.

 

 

 

 

 

3. Softener regenerates at

A.

Power failure or incorrect setting

A.

Restore power and reset time of day.

wrong time

 

 

 

 

 

 

 

 

 

4. Unit uses too much salt

A.

Improper salt setting

A.

Check salt usage and salt setting.

 

B.

Excessive water in brine tank

B.

Remove water. Clean drain line flow control,

 

 

 

 

brine line flow control, injector system and

 

 

 

 

brine valve.

 

 

 

 

 

5. Loss of water pressure

A.

Inlet to control blocked with iron

A.

Clean line to water softener. Remove piston

 

 

buildup or foreign matter

 

and clean control.

 

B.

Iron buildup in water conditioner

B.

Clean control and add resin cleaner to resin

 

 

 

 

bed.

 

 

 

 

 

6. Iron in conditioned water

A.

Fouled resin bed

A.

Check backwash, brine draw and brine tank

 

 

 

 

fill. Clean control and add resin cleaner to

 

 

 

 

resin bed.

 

 

 

 

 

7. Softener fails to draw brine

A.

Drain line flow control is plugged

A.

Clean drain line flow control.

 

B.

Brine line flow control is plugged

B. Clean drain line flow control.

 

C.

Injector assembly is plugged

C. Clean/replace injectors and screen.

 

D.

Line pressure is too low

D.

Increase line pressure. Line pressure must

 

 

 

 

be at least 20 psi (139.9 KPa) at all times.

 

E.

Internal control leak

E.

Change seals and spacers and/or piston

 

 

 

 

assembly.

 

 

 

 

 

8. Drain flows continuously

A.

Foreign material in control

A.

Remove piston assembly and inspect bore,

 

 

 

 

remove foreign material and check control in

 

 

 

 

various regeneration positions.

 

B.

Internal control leak

B. Replace seals and/or piston assembly.

 

C. Control valve is jammed in brine or

C.

Replace piston and seals and spacers.

 

 

backwash position

 

 

 

D.

Drive motor stopped or jammed

D.

Replace drive motor.

 

 

 

 

 

9. Softener fails to regenerate

A.

No salt in brine tank

A.

Add salt.

 

B.

Injector assembly plugged

B. Clean/replace injectors and screen.

 

C.

Salt bridged

C. Break salt bridging – see page 5.

 

D.

Insufficient salt used per regeneration

D. Check and adjust salt setting.

 

E.

Softener capacity too small

E. Replace softener with larger unit.

 

 

 

 

 

10. Softener regenerates every

A.

Softener capacity too small

A.

Replace with larger unit.

night

 

 

 

 

 

 

 

 

 