Symptom/Error FRU/Action in Sequence
02B2
Incorrect
Drive A type
— run
SETUP
1. Check that the drive is defined with
the proper diskette type in BIOS
Setup Utility.
2. Go to “Diskette Drive Checkout” on
page 25.
02D0
System
cache error
— Cache dis-
abled
1. CPU card
2. Planar board
02F0
CPU ID:
1. CPU card
2. Planar board
02F5
DMA Test
Failed
1. DIMM
2. CPU card
3. Planar board
02F6
Software NMI
Failed
1. DIMM
2. CPU card
3. Planar board
02F7
Fail-Safe
Timer NMI
Failed
1. DIMM
2. CPU card
3. Planar board
Error MessagesSymptom/Error FRU/Action in Sequence
Device
Address Con-
flict
1. Load Setup Defaults in BIOS Setup
Utility.
2. Backup battery (RTC)
3. Planar board
Allocation
Error for:
device
1. Load Setup Defaults in BIOS Setup
Utility.
2. Backup battery (RTC)
3. Planar board
Failing Bits:
nnnn 1. DIMM
2. BIOS ROM
3. Planar board
Invalid
System Con-
figuration
Data
1. BIOS ROM
2. Planar board
I/O device
IRQ conflict 1. Load Setup Defaults in BIOS Setup
Utility.
2. Backup battery (RTC)
3. Planar board
36 ThinkPad 390/i Series 1700