Hinge, and Inverter: Important: After you
replace the LCD or inverter, follow the instructions in
“Setting Inverter ID” on page 30.
Note: For DSTN LCDs, a tape is used to secure the LCD
FPC cable after it is connected to the LCD. This tape is a
special tape with safety characteristics, and is part of the
Mylar FRU. Removing Procedures:
Remove LCD: .1/→.2/→.3/
Remove Inverter: .1/→.2/→.3/→.4/ →.5/
Remove Left Hinge: .6/→.7/
Remove LCD FPC cable: .1/→.2/→.3/→.4/
→.5/→.6/→.7/
Note: Make sure you use the correct screw when
replacing.
Step Size
(Quantity) Head and
Color Memo
.1/ M3 x 6L (4) Bind head,
silver
.4/ M2 x 3L (2) Pan head,
silver
.7/ M2.5 x 6L (2) Pan head,
black w/ nylock
paste